EUVIMEDEUVIMED entdecken
Crossref

The effect of tidal volume on fluid responsiveness assessment using pulse pressure variations and velocity time integral variations in patients with septic shock

Mario A. Todary, Ahmed M. Nabil, Ehab M. El Reweny

Research and Opinion in Anesthesia & Intensive Care · 2020

DOI: 10.4103/roaic.roaic_124_19 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Research and Opinion in Anesthesia & Intensive Care, 2020. Verfasst von Mario A. Todary und 2 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Expanding volume in septic shock can be a source of therapeutic dilemma. On one hand, the severity of the disease necessitates administration of fluids. On the other hand, it has now been clearly demonstrated that fluid overload has bad consequences. Many parameters were introduced to assess fluid responsiveness in patients with septic shock such as pulse pressure variations (PP%) and velocity time integral variations (VTI%).

Objective

The aim of this study was to determine whether the change in tidal volume introduced to patients with septic shock on mechanical ventilation would affect the values of PP% and VTI% of fluid responsiveness. Patients and methods In this prospective observational study, 60 mechanically ventilated patients with septic shock were enrolled. On admission, all patients received sedation and muscle relaxant to avoid any spontaneous breath. A fluid challenge in the form of 400 ml of normal saline 0.9% was given to all patients. However, before giving the normal saline to the patient, PP% and VTI% were measured when patient was given tidal volume 6 ml/kg and then when patient was given tidal volume 10 ml/kg. The same measures were repeated with the same tidal volumes, 1 min after giving the normal saline.

Results

A total of 31 patients were identified as fluid responders, whereas 29 patients were fluid nonresponders. In responders, the mean value of change of PP% with fluid challenge decreased significantly when increasing tidal volume from 6 to10 ml/kg, whereas the mean value of change of VTI% decreased insignificantly with tidal volume change.

Conclusion

PP% could be a reliable predictor of fluid responsiveness in patients with septic shock on a higher tidal volume ventilation, unlike VTI% which could be reliable at low tidal volume.

Zitieren

APA

Todary, M. A., Nabil, A. M., & Reweny, E. M. E. (2020). The effect of tidal volume on fluid responsiveness assessment using pulse pressure variations and velocity time integral variations in patients with septic shock. Research and Opinion in Anesthesia & Intensive Care. https://doi.org/10.4103/roaic.roaic_124_19

Vancouver

Todary MA, Nabil AM, Reweny EME. The effect of tidal volume on fluid responsiveness assessment using pulse pressure variations and velocity time integral variations in patients with septic shock. Research and Opinion in Anesthesia & Intensive Care. 2020. doi:10.4103/roaic.roaic_124_19

BibTeX
@article{Todary2020,
  author = {Todary, Mario A. and Nabil, Ahmed M. and Reweny, Ehab M. El},
  title = {The effect of tidal volume on fluid responsiveness assessment using pulse pressure variations and velocity time integral variations in patients with septic shock},
  journal = {Research and Opinion in Anesthesia & Intensive Care},
  year = {2020},
  doi = {10.4103/roaic.roaic_124_19}
}
Kostenlos starten →