A simplification of intricate multifocal electroretinogram understanding: A mini-review
Oman Journal of Ophthalmology · 2024-01 · 17 (1) · 11-18
DOI: 10.4103/ojo.ojo_48_23 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Oman Journal of Ophthalmology, online erschienen am 21.02.2024. Verfasst von Ai-Hong Chen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Optometry, iROViS, Faculty of Health Sciences, Universiti Teknologi MARA, Cawangan Selangor, Kampus Puncak Alam, Bandar Puncak Alam, Selangor Darul E…. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Variation of multifocal electroretinogram (mfERG) data presentation in existing scientific publications is a challenge for eye care practitioners to apply the scientific information for evidence-based practice in patient management. This review offers an overview of the mfERG data presentation types. Eight types of data presentation in the form of a table, scatter plot, line graph, bar graph/box plot, single waveform/a group of waveforms, trace array topography, three-dimensional topography, and two-dimensional topography are identified. The table format is used to provide the exact values. Line graphs, scatter, and box plots offer information about the relationship of mfERG values. Waveforms are helpful for comparison between groups or conditions. Topographies outline the retinal, especially the specific localized retinal abnormalities. An infographic of fundamental mfERG electrical response with definitions and clinical indications is provided to bridge the gap between researchers and clinicians to facilitate efficient clinical application.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Optometry, iROViS, Faculty of Health Sciences, Universiti Teknologi MARA, Cawangan Selangor, Kampus Puncak Alam, Bandar Puncak Alam, Selangor Darul Ehsan, Malaysia.
- MATA by Optometrist, Jalan Niaga Bestari, Puncak Bestari, Puncak Alam, Selangor, Malaysia.
Zitieren
APA
Chen, A. H., Rafiuddin, M. S. M., Ahmad, A., & Rosli, S. A. (2024). A simplification of intricate multifocal electroretinogram understanding: A mini-review. Oman Journal of Ophthalmology, 17(1), 11-18. https://doi.org/10.4103/ojo.ojo_48_23
Vancouver
Chen AH, Rafiuddin MSM, Ahmad A, Rosli SA. A simplification of intricate multifocal electroretinogram understanding: A mini-review. Oman Journal of Ophthalmology. 2024;17(1):11-18. doi:10.4103/ojo.ojo_48_23
BibTeX
@article{Chen2024,
author = {Chen, Ai-Hong and Rafiuddin, Muhamad Syukri Mohamad and Ahmad, Azmir and Rosli, Saiful Azlan},
title = {A simplification of intricate multifocal electroretinogram understanding: A mini-review},
journal = {Oman Journal of Ophthalmology},
year = {2024},
volume = {17},
number = {1},
pages = {11--18},
doi = {10.4103/ojo.ojo_48_23}
}
EUVIMED