Clinical profile and inventory gaps for extreme power intraocular lens implantation
Odisha Journal of Ophthalmology · 2025-07 · 32 (2) · 74-78
DOI: 10.4103/odjo.odjo_17_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Odisha Journal of Ophthalmology, online erschienen am 13.07.2026. Verfasst von Shiva Prasad Sahoo und 8 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
The purpose of the study was to evaluate visual outcomes in eyes implanted with extreme power intraocular lenses (IOLs) and to assess the impact of institutional inventory gaps on surgical wait time. Materials and Methods: A retrospective observational study was conducted at a secondary eye care center in Sambalpur, Odisha. IOL powers from 7948 cataract surgeries performed between March 2024 and March 2025 were analyzed to establish an institution-specific definition. Powers +30 D (±2 standard deviation of institutional mean) were classified as extreme. A total of 104 eyes met the inclusion criteria.
Results
Mean best-corrected visual acuity improved significantly from 1.61 ± 0.46 to 0.43 ± 0.25 logMAR ( P < 0.001), with 75.3% of eyes achieving ≥6/18 vision. Eyes requiring high-power IOLs (>+30 D) had a significantly longer mean surgical wait time (14.92 ± 7.04 days) compared to low-power eyes (
Zitieren
APA
Sahoo, S. P., Ray, A., Sahoo, S. N., Satapathy, S. K., Khandelwal, M., Chandran, S., Pati, M., Swarnkar, S., & Shendey, S. (2025). Clinical profile and inventory gaps for extreme power intraocular lens implantation. Odisha Journal of Ophthalmology, 32(2), 74-78. https://doi.org/10.4103/odjo.odjo_17_26
Vancouver
Sahoo SP, Ray A, Sahoo SN, Satapathy SK, Khandelwal M, Chandran S, et al. Clinical profile and inventory gaps for extreme power intraocular lens implantation. Odisha Journal of Ophthalmology. 2025;32(2):74-78. doi:10.4103/odjo.odjo_17_26
BibTeX
@article{Sahoo2025,
author = {Sahoo, Shiva Prasad and Ray, Arkaprava and Sahoo, Sindhu Nandini and Satapathy, Sugyani Kumari and Khandelwal, Madhuri and Chandran, Sreeja and Pati, Monalisa and Swarnkar, Sourabh and Shendey, Sangharsha},
title = {Clinical profile and inventory gaps for extreme power intraocular lens implantation},
journal = {Odisha Journal of Ophthalmology},
year = {2025},
volume = {32},
number = {2},
pages = {74--78},
doi = {10.4103/odjo.odjo_17_26}
}