Evaluation of stress and strain distribution in and around orthodontic extra-alveolar mini-implants in the Infrazygomatic Crest region during retraction of teeth: A Finite Element Method Study

Diptiman Shukla, T P Chaturvedi, S K Panda

National Journal of Maxillofacial Surgery · 2026-01 · 17 (1) · 86-93

DOI: 10.4103/njms.njms_40_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift National Journal of Maxillofacial Surgery, online erschienen am 30.04.2026. Verfasst von Diptiman Shukla und 2 weiteren Autor:innen. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Precise anchorage control is critical for predictable orthodontic tooth movement. Extra-alveolar mini-implants in the infrazygomatic crest (IZC) region benefit from robust cortical bone; however, the distribution of stress—and thus long-term stability—is heavily influenced by implant design, insertion angle, and force orientation. Finite element analysis (FEA) offers the robust method for simulating these biomechanical interactions.

Objective

The study aims to evaluate von Mises stress distribution patterns in mini-implants and surrounding bone at various placement angles and force directions in the IZC region using finite element method (FEM), with the goal of determining the configuration that minimizes peak stress and optimizes load transfer. Material and Methods: Two 3D FEM models were generated to simulate orthodontic force applications on mini-implants with different geometric parameters and insertion angles. A static load of 3 N was applied to the implant head from three directions (horizontal, oblique, vertical) over four defined insertion angles. FE simulations were performed using Ansys Workbench v24 (a software developed and manufactured by ANSYS, Inc., Pennsylvania, USA & distributed in India by INNOVENT Eng. solutions Pvt. Ltd, Bangalore-560038) to analyses stress and strain distributions.

Results

Simulations revealed that the highest von Mises stress localizes at the implant neck and adjacent cortical bone. Lower insertion angles (40°–50°) produced a more uniform stress distribution and reduced peak values compared to higher angles (60°–70°). Maximum von Mises stress was observed in the mini-implant of 20.05 MPa, in cortical bone of 10.94 MPa, and in cancellous bone of 0.79 MPa.

Conclusion

The data indicate that mini-implant insertion angle between 40° and 50° in the IZC region minimizes critical stress concentrations, likely enhancing implant stability. Furthermore, the VectorTAS system generally exhibits lower screw stress than the Osstem model; however, both designs operate within the safe fatigue limits of titanium. These findings underscore the utility of FEA in optimizing implant design and surgical protocols for clinical success.

Zitieren

APA

Shukla, D., Chaturvedi, T. P., & Panda, S. K. (2026). Evaluation of stress and strain distribution in and around orthodontic extra-alveolar mini-implants in the Infrazygomatic Crest region during retraction of teeth: A Finite Element Method Study. National Journal of Maxillofacial Surgery, 17(1), 86-93. https://doi.org/10.4103/njms.njms_40_25

Vancouver

Shukla D, Chaturvedi TP, Panda SK. Evaluation of stress and strain distribution in and around orthodontic extra-alveolar mini-implants in the Infrazygomatic Crest region during retraction of teeth: A Finite Element Method Study. National Journal of Maxillofacial Surgery. 2026;17(1):86-93. doi:10.4103/njms.njms_40_25

BibTeX
@article{Shukla2026,
  author = {Shukla, Diptiman and Chaturvedi, T P and Panda, S K},
  title = {Evaluation of stress and strain distribution in and around orthodontic extra-alveolar mini-implants in the Infrazygomatic Crest region during retraction of teeth: A Finite Element Method Study},
  journal = {National Journal of Maxillofacial Surgery},
  year = {2026},
  volume = {17},
  number = {1},
  pages = {86--93},
  doi = {10.4103/njms.njms_40_25}
}