EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Audit on the Quality of Orthodontic Clinical Photographs in Ministry of Health Orthodontic Clinic, Kota Kinabalu, Sabah, Malaysia

Wai Yan Har, Lynnora Patrick Majawit

Malaysian Dental Journal · 2026-04 · 49 (2) · 35-43

DOI: 10.4103/mdj.mdj_1_26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Malaysian Dental Journal, online erschienen am 09.07.2026. Verfasst von Wai Yan Har und 1 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Orthodontic clinical photographs are essential for accurate diagnosis, treatment planning and monitoring. Clinical photographs augment traditional records, such as study models and radiographs, by providing detailed documentation of soft-tissue and skeletal relationships.

Objectives

This audit aimed to assess the quality of orthodontic photographs taken at Queen Elizabeth II Hospital, determine if they met established standards and identify areas for improvement. Materials and Methods: A retrospective two-cycle audit was conducted. Cases with complete pre- and post-treatment photo sets were included. The first audit, conducted in 2019, evaluated 270 photographs from 15 cases in 2015, while the second audit, in 2024, assessed 522 images from 29 cases in 2023. Images were rated as good, acceptable or unacceptable by an orthodontist based on predefined criteria. The gold standard of this audit was to achieve 100% images with at least acceptable quality.

Results

In the first audit, only 51% of images were rated as good, 38% acceptable, and 11% unacceptable, with common errors including improper angulation, overcropping and poor focus. Following the identification of contributing factors and the implementation of corrective actions, the second audit revealed substantial improvement, with 89.8% of images rated as good, 9.6% acceptable and only 0.6% deemed unacceptable.

Conclusion

The gold standard was not fully achieved. Targeted interventions led to a marked improvement in the quality of orthodontic photographs. The implementation of standardized protocols is essential to ensure the sustained quality of orthodontic documentation. Continued audits are crucial to ensure consistent quality and strive to achieve the gold standard.

Zitieren

APA

Har, W. Y., & Majawit, L. P. (2026). Audit on the Quality of Orthodontic Clinical Photographs in Ministry of Health Orthodontic Clinic, Kota Kinabalu, Sabah, Malaysia. Malaysian Dental Journal, 49(2), 35-43. https://doi.org/10.4103/mdj.mdj_1_26

Vancouver

Har WY, Majawit LP. Audit on the Quality of Orthodontic Clinical Photographs in Ministry of Health Orthodontic Clinic, Kota Kinabalu, Sabah, Malaysia. Malaysian Dental Journal. 2026;49(2):35-43. doi:10.4103/mdj.mdj_1_26

BibTeX
@article{Har2026,
  author = {Har, Wai Yan and Majawit, Lynnora Patrick},
  title = {Audit on the Quality of Orthodontic Clinical Photographs in Ministry of Health Orthodontic Clinic, Kota Kinabalu, Sabah, Malaysia},
  journal = {Malaysian Dental Journal},
  year = {2026},
  volume = {49},
  number = {2},
  pages = {35--43},
  doi = {10.4103/mdj.mdj_1_26}
}
Kostenlos starten →