Abstract (Originalsprache)
Purpose
To compare visual performance and functional outcomes of TECNIS Synergy multifocal intraocular lens (IOL) versus Acrysof PanOptix IOL in patients undergoing bilateral cataract surgery.
Setting
A tertiary care eye hospital.
Design
A prospective, randomized, comparative study. Materials and Methods: Patients 22 years or older were randomly assigned to bilateral implantation with TECNIS Synergy or Acrysof PanOptix multifocal IOLs. The end points included mean uncorrected monocular distance visual acuity (UDVA), monocular uncorrected near visual acuity (UNVA), monocular uncorrected intermediate visual acuity (UIVA), contrast sensitivity, and nondirected patient responses to a visual symptoms’ questionnaire.
Results
A total of 120 eyes (60 patients—30 in each group) were evaluated over 6 months. Most patients in both groups achieved 20/20 or better monocular UDVA (93% vs 95%). Most patients achieved 20/25 or better monocular UNVA at 33 cm (73% vs 25%) and 20/21 at 40 cm (60% vs 93.33%). The mean between-group difference in monocular UNVA at 33 cm favored Synergy (95% confidence interval [CI]: 0.027–0.055; P ≤ 0.001), and that at 40 cm favored PanOptix (95% CI: 0.034–0.110; P ≤ 0.001). Binocular UDVA and UNVA were comparable in both groups. Objective monocular UIVA was comparable, whereas functional monocular UIVA at 60 cm with Salzburg Reading Desk was better in Synergy by 145.7 words per minute. Contrast sensitivity and patient-reported visual symptoms were similar.
Conclusion
Both IOLs showed similarly satisfactory performance, with Synergy having slightly better UNVA at 33 cm and PanOptix at 40 cm. IOLs should be selected based on patients’ lifestyle and individual physiological needs.
Zitieren
APA
Ganesh, S., Pereira, S. S., Jafar, F. S., Sriganesh, S. S., & Sriganesh, S. S. (2026). Comparison of Functional and Visual Outcomes Following Bilateral Implantation of Two Diffractive Trifocal Intraocular Lenses. Journal of Vision Sciences, 5(1), 37-43. https://doi.org/10.4103/jvs.jvs_9_26
Vancouver
Ganesh S, Pereira SS, Jafar FS, Sriganesh SS, Sriganesh SS. Comparison of Functional and Visual Outcomes Following Bilateral Implantation of Two Diffractive Trifocal Intraocular Lenses. Journal of Vision Sciences. 2026;5(1):37-43. doi:10.4103/jvs.jvs_9_26
BibTeX
@article{Ganesh2026,
author = {Ganesh, Sri and Pereira, Savio Sylvan and Jafar, Faiza Syed and Sriganesh, Supriya Samak and Sriganesh, Sushmitha Samak},
title = {Comparison of Functional and Visual Outcomes Following Bilateral Implantation of Two Diffractive Trifocal Intraocular Lenses},
journal = {Journal of Vision Sciences},
year = {2026},
volume = {5},
number = {1},
pages = {37--43},
doi = {10.4103/jvs.jvs_9_26}
}
EUVIMED