EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Bent Ab Interno Needle Goniectomy (BANG): A Low-Cost, High-Yield Angle Procedure for Resource-Limited Settings

Soumya Ramani, Meghdeep J. Patil

Journal of Vision Sciences · 2026-01 · 5 (1) · 7-12

DOI: 10.4103/jvs.jvs_1_26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Vision Sciences, online erschienen am 11.11.2026. Verfasst von Soumya Ramani und 1 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose of Review: Trabecular meshwork (TM)-based minimally invasive glaucoma surgery (MIGS) has reshaped angle surgery for open-angle glaucoma, but device-dependent platforms remain financially inaccessible to a large proportion of glaucoma patients worldwide. Bent ab interno needle goniectomy (BANG) repurposes a standard disposable hypodermic needle into a goniectomy instrument, enabling TM excision at a fraction of the cost of proprietary MIGS devices. We review the technique, proposed mechanism, published outcomes, and comparative standing of BANG among contemporary angle-based MIGSs, with attention to its role in resource-limited settings. Recent Findings: Since its original description, BANG has been shown to lower intraocular pressure (IOP) by 24%–55% across heterogeneous cohorts of primary open-angle glaucoma, pseudoexfoliation glaucoma, and primary congenital glaucoma, with the medication burden falling by a comparable margin. Combined phacoemulsification-BANG series from India and its variants (Visco-BANG, B-BANG) report 12-month IOP reductions of 28%–32%, with a favorable safety profile dominated by self-limiting hyphema. A 2026 multi-arm comparative cohort (the SKIBI study) situates BANG alongside suture-gonioscopy-assisted transluminal trabeculotomy, Kahook Dual Blade (KDB), iStent, and iStent inject when combined with phacoemulsification, confirming statistically significant IOP and medication reduction with BANG that approaches device-based MIGS at a fraction of the cost. Summary: BANG achieves TM excision comparable in mechanism to KDB and Trabectome, using equipment present in every operating room. Comparative data suggest similar or only modestly lower efficacy relative to instrument-dependent MIGS, while avoiding implant cost, device amortization, and supply-chain dependence entirely. For surgeons in low- and middle-income countries managing a high volume of coexisting cataract and glaucoma, BANG offers a reproducible, inexpensive route to meaningful IOP control. Wider adoption, standardized technique reporting, and longer-term comparative trials are warranted.

Zitieren

APA

Ramani, S., & Patil, M. J. (2026). Bent Ab Interno Needle Goniectomy (BANG): A Low-Cost, High-Yield Angle Procedure for Resource-Limited Settings. Journal of Vision Sciences, 5(1), 7-12. https://doi.org/10.4103/jvs.jvs_1_26

Vancouver

Ramani S, Patil MJ. Bent Ab Interno Needle Goniectomy (BANG): A Low-Cost, High-Yield Angle Procedure for Resource-Limited Settings. Journal of Vision Sciences. 2026;5(1):7-12. doi:10.4103/jvs.jvs_1_26

BibTeX
@article{Ramani2026,
  author = {Ramani, Soumya and Patil, Meghdeep J.},
  title = {Bent Ab Interno Needle Goniectomy (BANG): A Low-Cost, High-Yield Angle Procedure for Resource-Limited Settings},
  journal = {Journal of Vision Sciences},
  year = {2026},
  volume = {5},
  number = {1},
  pages = {7--12},
  doi = {10.4103/jvs.jvs_1_26}
}
Kostenlos starten →