EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Comparison of respiratory rate oxygenation (ROX) and pediatric respiratory rate oxygenation (PROX) indices for predicting high-flow nasal cannula failure in children: A single-centre prospective observational study

Sana Gupta, Nitika Agrawal, Ashish Simalti

Journal of Pediatric Critical Care · 2026-07 · 13 (4) · 217-222

DOI: 10.4103/jpcc.jpcc_37_26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Pediatric Critical Care, online erschienen am 13.08.2026. Verfasst von Sana Gupta und 2 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

High-flow nasal cannula (HFNC) is increasingly used to manage pediatric respiratory distress, but delayed recognition of HFNC failure can worsen outcomes. The respiratory rate-oxygenation (ROX) index predicts HFNC response but is limited by age-related variability in respiratory rate. The pediatric respiratory rate-oxygenation (PROX) index standardizes respiratory rate and may improve early prediction. This study aimed to compare the diagnostic accuracy of ROX and PROX for predicting HFNC failure in children. Subjects and Methods: This prospective observational study included children aged 1 month–18 years who were initiated on HFNC. ROX and PROX were calculated at initiation, 2 h, and 6 h. HFNC failure was defined as escalation of respiratory support within 48 h. Discrimination was assessed by receiver operating characteristic analysis; optimal cutoffs were derived using the Youden index.

Results

Ninety children were enrolled; 19 (21.1%) required escalation. Both indices differed significantly between failure and success groups at all-time points ( P < 0.001). At initiation, PROX showed superior discrimination (area under the curve [AUC]: 0.852) versus ROX (AUC: 0.725). At 2 h, PROX outperformed ROX (AUC: 0.971 vs. 0.848), with higher specificity (91.5%) and accuracy (90.8%). By 6 h, both indices demonstrated excellent predictive performance.

Conclusions

Both ROX and PROX predict HFNC failure in children. PROX provides superior early diagnostic accuracy, supporting its use for early bedside risk stratification and timely escalation of respiratory support.

Zitieren

APA

Gupta, S., Agrawal, N., & Simalti, A. (2026). Comparison of respiratory rate oxygenation (ROX) and pediatric respiratory rate oxygenation (PROX) indices for predicting high-flow nasal cannula failure in children: A single-centre prospective observational study. Journal of Pediatric Critical Care, 13(4), 217-222. https://doi.org/10.4103/jpcc.jpcc_37_26

Vancouver

Gupta S, Agrawal N, Simalti A. Comparison of respiratory rate oxygenation (ROX) and pediatric respiratory rate oxygenation (PROX) indices for predicting high-flow nasal cannula failure in children: A single-centre prospective observational study. Journal of Pediatric Critical Care. 2026;13(4):217-222. doi:10.4103/jpcc.jpcc_37_26

BibTeX
@article{Gupta2026,
  author = {Gupta, Sana and Agrawal, Nitika and Simalti, Ashish},
  title = {Comparison of respiratory rate oxygenation (ROX) and pediatric respiratory rate oxygenation (PROX) indices for predicting high-flow nasal cannula failure in children: A single-centre prospective observational study},
  journal = {Journal of Pediatric Critical Care},
  year = {2026},
  volume = {13},
  number = {4},
  pages = {217--222},
  doi = {10.4103/jpcc.jpcc_37_26}
}
Kostenlos starten →