Comparative Evaluation of the Efficacy of Four Tubular Occlusion Agents in Human Dentin After in-Office Tooth Bleaching by Scanning Electron Microscopy Analysis: An In Vitro Study

Soumia Kurian, Rethi Gopakumar, Faisal M A Gaffoor, NC Sajeena, B Arunima, Lamiya Kamal

Journal of Pharmacy and Bioallied Sciences · 2026-10 · 18 (4) · 365-369

DOI: 10.4103/jpbs.jpbs_272_26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Pharmacy and Bioallied Sciences, online erschienen am 17.11.2026. Verfasst von Soumia Kurian und 5 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A BSTRACT Background: Post-bleaching dentinal hypersensitivity is a common complication of in-office tooth bleaching caused by increased dentinal permeability. This study compared the dentinal tubule occluding efficacy of four desensitizing agents following bleaching using scanning electron microscopy (SEM). Materials and methods: Sixty-five extracted human mandibular premolars were bleached with 35% hydrogen peroxide and randomly allocated into five groups ( n = 13): control, 940-nm diode laser, Tokuyama Shield Force Plus, stannous fluoride dentifrice, and NovaMin® dentifrice. Following treatment, dentinal tubule occlusion was evaluated by SEM at 2500 × magnification and expressed as the percentage of occluded tubules. Data were analyzed using one-way analysis of variance ( P < 0.05).

Results

All desensitizing treatments produced significantly greater tubule occlusion than the control ( P < 0.001). The diode laser showed the highest occlusion (99.39%), followed by Tokuyama Shield Force Plus (89.80%), NovaMin® (84.41%), and stannous fluoride (74.06%). SEM demonstrated near-complete tubule obliteration with the diode laser, a continuous resin seal with Tokuyama Shield Force Plus, mineral deposits with NovaMin®, and partial occlusion with stannous fluoride.

Conclusion

The 940-nm diode laser demonstrated the greatest dentinal tubule occlusion after in-office bleaching. Tokuyama Shield Force Plus and NovaMin® also showed substantial efficacy, suggesting that laser-assisted and resin-based desensitization may provide effective management of post-bleaching dentinal hypersensitivity.

Zitieren

APA

Kurian, S., Gopakumar, R., Gaffoor, F. M. A., Sajeena, N., Arunima, B., & Kamal, L. (2026). Comparative Evaluation of the Efficacy of Four Tubular Occlusion Agents in Human Dentin After in-Office Tooth Bleaching by Scanning Electron Microscopy Analysis: An In Vitro Study. Journal of Pharmacy and Bioallied Sciences, 18(4), 365-369. https://doi.org/10.4103/jpbs.jpbs_272_26

Vancouver

Kurian S, Gopakumar R, Gaffoor FMA, Sajeena N, Arunima B, Kamal L. Comparative Evaluation of the Efficacy of Four Tubular Occlusion Agents in Human Dentin After in-Office Tooth Bleaching by Scanning Electron Microscopy Analysis: An In Vitro Study. Journal of Pharmacy and Bioallied Sciences. 2026;18(4):365-369. doi:10.4103/jpbs.jpbs_272_26

BibTeX
@article{Kurian2026,
  author = {Kurian, Soumia and Gopakumar, Rethi and Gaffoor, Faisal M A and Sajeena, NC and Arunima, B and Kamal, Lamiya},
  title = {Comparative Evaluation of the Efficacy of Four Tubular Occlusion Agents in Human Dentin After in-Office Tooth Bleaching by Scanning Electron Microscopy Analysis: An In Vitro Study},
  journal = {Journal of Pharmacy and Bioallied Sciences},
  year = {2026},
  volume = {18},
  number = {4},
  pages = {365--369},
  doi = {10.4103/jpbs.jpbs_272_26}
}
Kostenlos starten →