Comparative evaluation of flexural strength and color stability of Omnichroma composite incorporated with Titanium dioxide nanoparticles and Chitosan nanoparticles – An In-vitro study
Journal of Oral Research and Review · 2026-07 · 18 (2) · 164-169
DOI: 10.4103/jorr.jorr_129_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Oral Research and Review, online erschienen am 17.07.2026. Verfasst von K. Gayathri und 5 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Composites resin is the sort after restorative material for esthetics. A variety of changes are made to improve the mechanical properties and esthetic durability of composite resin restoration. To compare the flexural strength and color stability of Omnichroma composite when incorporated with titanium dioxide nanoparticles (TiO 2 -NPs) and chitosan NPs (Ch-NPs). Materials and Methods: Thirty-six samples of rod-shaped omnichroma blocks were prepared for testing flexural strength using a three-point bending test, while disc-shaped blocks were used for testing color stability using an spectrophotometer. The samples were categorized into three groups ( n = 12) as Group 1%–1% TiO 2 -NPs incorporated omnichroma, Group 2%–1% Ch-NPs incorporated omnichroma, and Group 3-Omnichroma (control). They were further subdivided into Groups 1a, 1b, 2a, 2b, 3a, and 3b where groups 1a, 2a, and 3a ( n = 6 each) were tested for flexural strength and groups 1b, 2b, and 3b ( n = 6 each) were tested for color stability. Test blocks were kept in distilled water for 24 hrs. Data were performed using the one-way ANOVA and Tukey’s post hoc test.
Results
Omnichroma showed highest flexural strength (113.95 ± 11.01Mpa) followed by TiO 2 -NPs (31.02 ± 5.27 Mpa) and Ch-NPs (28.82 ± 3.70 Mpa) incorporated Omnichroma respectively. Highest color change was exhibited with TiO 2 -NPs addition than Ch-NPs in omnichroma.
Conclusions
The flexural strength of Omnichroma has decreased with the addition of 1% TiO 2 and 1% Ch-NPs. A clinically acceptable color shift on omnichroma is demonstrated by addition of 1% Ch-NPs.
Zitieren
APA
Gayathri, K., Nandhini, G., Chandrasekaran, C., Lakshmaiah, D., Karunakaran, J., & Kadandale, S. (2026). Comparative evaluation of flexural strength and color stability of Omnichroma composite incorporated with Titanium dioxide nanoparticles and Chitosan nanoparticles – An In-vitro study. Journal of Oral Research and Review, 18(2), 164-169. https://doi.org/10.4103/jorr.jorr_129_25
Vancouver
Gayathri K, Nandhini G, Chandrasekaran C, Lakshmaiah D, Karunakaran J, Kadandale S. Comparative evaluation of flexural strength and color stability of Omnichroma composite incorporated with Titanium dioxide nanoparticles and Chitosan nanoparticles – An In-vitro study. Journal of Oral Research and Review. 2026;18(2):164-169. doi:10.4103/jorr.jorr_129_25
BibTeX
@article{Gayathri2026,
author = {Gayathri, K. and Nandhini, G. and Chandrasekaran, Charanya and Lakshmaiah, Deepika and Karunakaran, Janani and Kadandale, Sadasiva},
title = {Comparative evaluation of flexural strength and color stability of Omnichroma composite incorporated with Titanium dioxide nanoparticles and Chitosan nanoparticles – An In-vitro study},
journal = {Journal of Oral Research and Review},
year = {2026},
volume = {18},
number = {2},
pages = {164--169},
doi = {10.4103/jorr.jorr_129_25}
}
EUVIMED