Differences and Limits of Agreement Among Pentacam, Corvis-St, and Iol-Master 700 Optical Biometric Devices Regarding Central Corneal Thickness Measurements
Journal of Current Ophthalmology · 2022-01 · 34 (1) · 44-49
DOI: 10.4103/joco.joco_96_21 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Current Ophthalmology, 2022-01. Verfasst von Sattar Rajabi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Purpose
To investigate the differences and limits of agreement in measuring corneal thickness using Pentacam, Corvis, and intraocular lens (IOL)-Master 700 devices.
Methods
This study was conducted on 37 right eyes of 21 males and 16 females ( n = 37) with a mean age of 52.11 ± 6.30 years. The central corneal thickness was measured using three optical biometric devices, including Pentacam, Corvis, and IOL-Master 700. The inclusion criteria were normal eyes without any ophthalmological abnormalities, history of ocular pathology, or ocular surgery. The data obtained from these three devices were compared two by two. The correlation and agreement limits among them were analyzed using statistical techniques.
Results
The mean standard deviation differences between Pentacam and Corvis, Pentacam and IOL-Master 700, as well as Corvis and IOL-Master 700 regarding the corneal thickness measurement, were 22.13 ± 8.05, 7.91 ± 8.02, and 14.21 ± 9.85 μm, respectively, which were statistically significant ( P < 0.0001). Based on the investigation of the limits of agreement according to the Bland Altman method, the corresponding values between Pentacam and Corvis, Pentacam and IOL-Master 700, and Corvis and IOL-Master 700 were -16.2 to +15.4, -15.8 to +16.3, and -20.1 to +20.0 μm, respectively. Furthermore, the correlation coefficients of the measurements obtained by Pentacam and Corvis, Pentacam and IOL-Master 700, as well as Corvis and IOL-Master 700 were determined 0.957, 0.964, and 0.948, respectively ( P < 0.0001).
Conclusion
The results from this study indicate that the interchangeable use of these three devices is not appropriate due to statistically significant differences and broad limits of agreement among the three devices, especially between Corvis and IOL-Master 700.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Optometry, School of Rehabilitation Sciences, Iran University of Medical Sciences, Tehran, Iran.
- Department of Optometry, Iran University of Medical Sciences, Tehran, Iran.
- Department of Basic Sciences, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
- Internal Medical Clinic, Bank Melli Hospital, Tehran, Iran.
Zitieren
APA
Rajabi, S., Asharlous, A., Riazi, A., Khabazkhoob, M., & Moalej, A. (2022). Differences and Limits of Agreement Among Pentacam, Corvis-St, and Iol-Master 700 Optical Biometric Devices Regarding Central Corneal Thickness Measurements. Journal of Current Ophthalmology, 34(1), 44-49. https://doi.org/10.4103/joco.joco_96_21
Vancouver
Rajabi S, Asharlous A, Riazi A, Khabazkhoob M, Moalej A. Differences and Limits of Agreement Among Pentacam, Corvis-St, and Iol-Master 700 Optical Biometric Devices Regarding Central Corneal Thickness Measurements. Journal of Current Ophthalmology. 2022;34(1):44-49. doi:10.4103/joco.joco_96_21
BibTeX
@article{Rajabi2022,
author = {Rajabi, Sattar and Asharlous, Amir and Riazi, Abbas and Khabazkhoob, Mehdi and Moalej, Alireza},
title = {Differences and Limits of Agreement Among Pentacam, Corvis-St, and Iol-Master 700 Optical Biometric Devices Regarding Central Corneal Thickness Measurements},
journal = {Journal of Current Ophthalmology},
year = {2022},
volume = {34},
number = {1},
pages = {44--49},
doi = {10.4103/joco.joco_96_21}
}
EUVIMED