EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Comparative Evaluation of Water Drinking Test Response in Advanced Glaucoma Patients with Prior Preserflo MicroShunt and Trabeculectomy Surgery

Sharon Yet Xue Er, Puspha Raman

Journal of Current Ophthalmology · 2026-01 · 38 (1) · 27-30

DOI: 10.4103/joco.joco_302_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Current Ophthalmology, online erschienen am 06.08.2026. Verfasst von Sharon Yet Xue Er und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Hospital Tuanku Jaafar, Seremban, Malaysia. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the differences in intraocular pressure (IOP) response to the water drinking test (WDT) in advanced glaucoma patients following trabeculectomy or Preserflo MicroShunt implantation.

Methods

This prospective study included 30 eyes from 29 advanced glaucoma patients: 15 underwent trabeculectomy, and 15 received the Preserflo MicroShunt. Baseline IOP was measured using Goldmann applanation tonometry, followed by WDT involving the consumption of 10 mL of water per kilogram of body weight over 5 min. IOP was measured at 15-min intervals until it returned to baseline. Outcomes included peak IOP, time to peak IOP, IOP fluctuation, and time to return to baseline.

Results

Baseline IOP was comparable between groups (trabeculectomy: 14.83 ± 2.28 mmHg; Preserflo: 15 ± 1.23 mmHg, P = 0.515). The peak IOP and IOP fluctuation were also similar ( P = 0.978 and P = 0.614, respectively). However, trabeculectomy patients exhibited a shorter time to peak IOP (27 ± 5.6 min vs. 36.25 ± 9.8 min, P = 0.017) and faster return to baseline (55 ± 4.8 min vs. 57.25 ± 9.8 min, P = 0.03).

Conclusions

Both trabeculectomy and the Preserflo MicroShunt effectively controlled IOP during WDT, with the Preserflo MicroShunt demonstrating noninferiority in overall IOP control. Trabeculectomy exhibited superior dynamic outflow capacity, making it suitable for patients requiring aggressive IOP reduction.

Schlagwörter

Stichwörter der Autor:innen

Advanced glaucomaGlaucoma surgeryIntraocular pressureMinimally invasive glaucoma surgeryPreserflo MicroShuntTrabeculectomyWater drinking test

Autor:innen und Institutionen

  • Department of Ophthalmology, Hospital Tuanku Jaafar, Seremban, Malaysia.
  • University Malaya Medical Center, Kuala Lumpur, Malaysia.
  • Department of Ophthalmology, CMH Specialist Hospital, Seremban, Malaysia.

Zitieren

APA

Xue Er, S. Y., & Raman, P. (2026). Comparative Evaluation of Water Drinking Test Response in Advanced Glaucoma Patients with Prior Preserflo MicroShunt and Trabeculectomy Surgery. Journal of Current Ophthalmology, 38(1), 27-30. https://doi.org/10.4103/joco.joco_302_25

Vancouver

Xue Er SY, Raman P. Comparative Evaluation of Water Drinking Test Response in Advanced Glaucoma Patients with Prior Preserflo MicroShunt and Trabeculectomy Surgery. Journal of Current Ophthalmology. 2026;38(1):27-30. doi:10.4103/joco.joco_302_25

BibTeX
@article{XueEr2026,
  author = {Xue Er, Sharon Yet and Raman, Puspha},
  title = {Comparative Evaluation of Water Drinking Test Response in Advanced Glaucoma Patients with Prior Preserflo MicroShunt and Trabeculectomy Surgery},
  journal = {Journal of Current Ophthalmology},
  year = {2026},
  volume = {38},
  number = {1},
  pages = {27--30},
  doi = {10.4103/joco.joco_302_25}
}
Kostenlos starten →