Augmented Renal Clearance is a Novel Entity of Outcome Impact in an Orthopedic Postoperative Septicemia Patient? A Case Report and a Review of Literature
Journal of Orthopaedic Association of South Indian States · 2026-01 · 23 (1) · 68-72
DOI: 10.4103/joasis.joasis_28_25 ↗Kurz gefasst
Fallbericht in der Zeitschrift Journal of Orthopaedic Association of South Indian States, online erschienen am 11.07.2026. Verfasst von M. Jyothiprasanth und 6 weiteren Autor:innen. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Augmented renal clearance (ARC) is a condition where kidney filtration rates exceed normal levels, often resulting in creatinine clearance above 130 mL/min/1.73 m. This complicates patient management, especially in septicemia, where precise antibiotic dosing is critical. A 48-year-old male with chronic liver disease, hypothyroidism, hypertension, and type II diabetes presented with medial colateral ligament (MCL) injury and underwent MCL repair. Postoperatively, he developed a surgical site infection and septicemia. Initial empirical antibiotics were adjusted based on culture results and his ARC, evidenced by a creatinine clearance of 237 mL/min at admission. Despite initial improvements, further surgical intervention and additional antibiotics were needed, leading to gradual recovery and discharge on oral antibiotics. Accurate renal function measurement is crucial for appropriate drug dosing in ARC to avoid subtherapeutic or toxic levels. Common formulas for estimating renal function include the Cockcroft–Gault and Modification of Diet in Renal Disease equations. ARC is prevalent in patients with trauma, surgery, or sepsis, complicating therapeutic management. Empirical broad-spectrum antibiotics in sepsis must be adjusted based on renal function and culture results to combat antimicrobial resistance. Managing ARC involves the risk of subtherapeutic dosing. Studies on ARC often have small sample sizes, single-center designs, and variability in definitions and patient demographics. Non-English research may also be overlooked.
Zitieren
APA
Jyothiprasanth, M., Jithin, C. R., Thomas, A. K., Mansoor, M. H., Ajinas, T. P., Sarang, P., & Aghosh, M. C. (2026). Augmented Renal Clearance is a Novel Entity of Outcome Impact in an Orthopedic Postoperative Septicemia Patient? A Case Report and a Review of Literature. Journal of Orthopaedic Association of South Indian States, 23(1), 68-72. https://doi.org/10.4103/joasis.joasis_28_25
Vancouver
Jyothiprasanth M, Jithin CR, Thomas AK, Mansoor MH, Ajinas TP, Sarang P, et al. Augmented Renal Clearance is a Novel Entity of Outcome Impact in an Orthopedic Postoperative Septicemia Patient? A Case Report and a Review of Literature. Journal of Orthopaedic Association of South Indian States. 2026;23(1):68-72. doi:10.4103/joasis.joasis_28_25
BibTeX
@article{Jyothiprasanth2026,
author = {Jyothiprasanth, M. and Jithin, C. R. and Thomas, Akhil K. and Mansoor, Mohamed Hadi and Ajinas, T. P. and Sarang, P. and Aghosh, M. C.},
title = {Augmented Renal Clearance is a Novel Entity of Outcome Impact in an Orthopedic Postoperative Septicemia Patient? A Case Report and a Review of Literature},
journal = {Journal of Orthopaedic Association of South Indian States},
year = {2026},
volume = {23},
number = {1},
pages = {68--72},
doi = {10.4103/joasis.joasis_28_25}
}
EUVIMED