EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

Gravity and Cryoprobe-assisted Carino-bronchial Ball-valve Tumour Debulking

Shagun Bhatia Shah, Swati Sahay, Rajiv Chawla, Sweta Gulati

Journal of Onco-Anaesthesiology and Perioperative Medicine · 2025

DOI: 10.4103/joapm.joapm_24_24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Onco-Anaesthesiology and Perioperative Medicine, 2025. Verfasst von Shagun Bhatia Shah und 3 weiteren Autor:innen. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dear Editor, One-quarter of lung cancer patients suffer from central airway obstruction.[1] Anaesthesia for tracheobronchial tumour debulking poses myriad challenges. Oxygenation is problematic, but ventilation is a bigger problem.[2] Our patient was 60 years old, 65 kg male on mechanical ventilatory support (sedated, paralysed and intubated) in the intensive care unit for a tracheobronchial tumour causing central airway obstruction. His heart rate was 136 beats/min (rising trend: 100–136 beats/min over 30 min) and arterial oxygen saturation (SpO2) was 94% at a fraction of inspired oxygen (FiO2) 1. SpO2 fell to 77% within 5 min on the transport ventilator while shifting to the major operation theatre (OT) for tracheal debulking surgery before the Perseus Anaesthesia workstation in the OT was connected. After 10 min of bagging in manual mode (650–700 mL tidal volume, FiO2 = 1, oxygen flush on and respiratory rate 25/min), the SpO2 reached 95%. Arterial blood gas (ABG) analysis revealed respiratory acidosis (partial pressure of arterial carbon dioxide PaCO2 – 160 mmHg; partial pressure of arterial oxygen PaO2 – 140 mmHg). After intravenous (IV) succinylcholine 50 mg, total IV anaesthesia with bispectral index-guided propofol infusion, intermittent fentanyl (20 µg), succinylcholine (10 mg) and glycopyrrolate (0.02 mg) boluses and hydrocortisone (100 mg) were employed. A fibre-optic bronchoscope was introduced through the pre-existing endotracheal tube (7.5 mmID) through a bronchoscope double swivel adapter with dual-use suctioning and a fibre-optic cap with an airtight seal. We realised that the transport ventilator had failed to deliver an adequate tidal volume, consequent to near-complete airway obstruction by an exophytic tumour originating in the left main bronchus, protruding past the carina into the trachea leaving a crescentic opening from 2 to 3 o’clock position that appeared during positive-pressure inspiration but almost vanished during expiration [Figure 1]. Despite adequate oxygenation, ventilation was hampered (inadequate expiratory volume due to the tumour behaving like a ball valve), leading to hypercarbia and accompanying refractory tachycardia. The crescentic channel was enlarged by fiber-optic bronchoscopic (4.9 mm OD) tumour coring, while positive pressure ventilation was maintained simultaneously. FiO2 was reduced to 0.4 during active cauterisation. The problem spot was the potential risk of the resected tumour slipping and plugging the right bronchus, jeopardising oxygenation. To avert this eventuality, the chest physicians requested right endobronchial intubation for continuous oxygenation of the right lung throughout coring, but this was not feasible for two reasons. First, the tumour was occluding the mouth of the right bronchus. Second, the glottis was not wide enough to accommodate both a rigid bronchoscope (11 mm OD) and an endobronchial microlaryngeal surgery tube. IV atracurium bolus 25 mg was administered after 130 mg succinylcholine effect had worn off to avoid Phase II block, followed by peripheral nerve stimulator-guided atracurium infusion. Tumour debulking allowed ventilation (fresh ABG showed PaCO2 – 78 mmHg). After 2 h of cauterisation using the flexible fiberscope, 20% of the tumour was resected. After extubation, a rigid bronchoscope was negotiated through the glottis for improved vision quality, airway control, suction capability, more extensive sample-sized material recovery, stent placement and multiple working channels. The potential for airway fires necessitates an obligatory low FiO2 (0.33–0.4) during tumour cauterisation. A flexible cryoprobe (1.7 mm OD) was used for debulking whenever SpO2 dropped below 92% during cauterisation because cryoablation does not heat up the tumour tissue. A manual jet ventilator was connected to the side port of the rigid bronchoscope [Figure 2]. After an hour of jet ventilation (driving pressure – 30 psi, rate – 40/min, I/E ratio – 1:3), tachycardia unresponsive to esmolol and metoprolol re-appeared. Since ETCO2 was unrecordable during jet ventilation, a repeat ABG (PaO2 – 118 mmHg; PaCO2 – 113 mmHg) was performed. Air entrainment (venturi effect) and convective ventilation (bulk flow) catered to oxygenation, but ventilation was erratic. Tachycardia improved once sufficient tumour was resected to allow CO2 elimination. After 3.5 h, the tumour could be resected from surrounding structures but was too unwieldy to be completely pinched by the grasping forceps. The patient was placed in the Trendelenberg’s position with the OT table tilted right side up. As feared, the tumour slipped from the grasping-forceps but gravitated away from the right bronchus by thoughtful patient positioning. A cryoprobe was fixed to the tumour; this time, it could be gently delivered from the rigid bronchoscope. Jet ventilation was suspended during tumour delivery lest the blast dislodge the tumour. The patient was shifted to post-operative ventilatory support without reversing the neuromuscular block.Figure 1: Bronchoscopic images of the left tracheo-bronchial tumour towards beginning (a) and after completion of tracheal coring (b)Figure 2: Rigid bronchoscope, fibreoptic bronchoscope, cryoprobe assembly (a); Jet ventilation via rigid bronchoscope (b). FOB: Fibreoptic bronchoscopeCryoablation, although slower, allows tracheobronchial tumour resection even at high FiO2 sans any danger of airway fire, unlike electrocautery. Moreover, the cryoprobe has a small footprint, and the tumour is unlikely to slip from its grip unless thawed. Cryotherapy is user-friendly and safe (no risk of bronchial perforation, radiation, electrical accidents or fires).[3] Classic apnoeic oxygenation entails a 2.6–3.4 mmHg/min rise in PaCO2, transnasal humidified rapid-insufflation ventilatory exchange reduces this to 1.12 mmHg/min, while supraglottic jet oxygenation-ventilation through the Wei nasal tube curbs full form-retention.[4,5] Considering potential cautery-induced airway fires on insufflating 70 L/min of 100% oxygen, the latter two techniques were rejected. Coordinated efforts of the interventional bronchoscopists and anaesthesiologists on the shared airway led to a positive outcome. Declaration of patient consent The authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given his consent for his images and other clinical information to be reported in the journal. The patient understands that name and initials will not be published and due efforts will be made to conceal identity, but anonymity cannot be guaranteed. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.

Zitieren

APA

Shah, S. B., Sahay, S., Chawla, R., & Gulati, S. (2025). Gravity and Cryoprobe-assisted Carino-bronchial Ball-valve Tumour Debulking. Journal of Onco-Anaesthesiology and Perioperative Medicine. https://doi.org/10.4103/joapm.joapm_24_24

Vancouver

Shah SB, Sahay S, Chawla R, Gulati S. Gravity and Cryoprobe-assisted Carino-bronchial Ball-valve Tumour Debulking. Journal of Onco-Anaesthesiology and Perioperative Medicine. 2025. doi:10.4103/joapm.joapm_24_24

BibTeX
@article{Shah2025,
  author = {Shah, Shagun Bhatia and Sahay, Swati and Chawla, Rajiv and Gulati, Sweta},
  title = {Gravity and Cryoprobe-assisted Carino-bronchial Ball-valve Tumour Debulking},
  journal = {Journal of Onco-Anaesthesiology and Perioperative Medicine},
  year = {2025},
  doi = {10.4103/joapm.joapm_24_24}
}
Kostenlos starten →