EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Noise During Anesthetic Induction in Obstetric Operating Rooms: A Prospective Observational Study

Abhishek Moses, Vighnesh Ashok, Ishwar Bhukal, Vanita Jain

Journal of Obstetric Anaesthesia and Critical Care · 2026-07 · 16 (2) · 135-138

DOI: 10.4103/joacc.joacc_18_26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Obstetric Anaesthesia and Critical Care, online erschienen am 03.08.2026. Verfasst von Abhishek Moses und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Excessive noise in the operating room during anesthetic induction has shown to have negative consequences for healthcare workers and patients. Data regarding noise levels during anesthetic induction in obstetric theaters in India is lacking.

Aim

Report noise during anesthetic induction for caesarean deliveries.

Methods

One hundred patients scheduled for caesarean delivery were recruited. Baseline, time-weighted (TW) maximum, minimum and average, and peak noise levels were measured during anesthetic induction using a decibel meter (Decibel X Software, SkyPaw Co Ltd, Hanoi, Vietnam). At the end of surgery, patients reported their satisfaction with OR noise on a 5-point Likert scale.

Results

The overall mean TW average and maximum noise were 32.4 ± 7.51 dBA and 56.02 ± 6.74 dBA, respectively. The mean TW average dBA did not differ significantly between elective ( n = 47) and emergency ( n = 53) caesarean deliveries [32.64 ± 4.32 vs. 32.18 ± 9.46, MD (95%CI) –0.46 (–3.33 to 2.52), P = 0.76]. The mean TW average dBA was significantly lower in caesarean deliveries done at night ( n = 38) compared to those done in the day ( n = 62) [30.78 ± 5.08 vs. 34.27 ± 6.90, MD (95%CI) –3.49 (–6.05 to –0.92), P = 0.008]. 92 (92%) patients reported being satisfied with the noise levels during anesthetic induction.

Conclusion

The TW average noise levels reported in our study were within the recommendation of ≤45 dBA for hospitals. Mean TW average noise levels during anesthetic induction in our obstetric theaters did not differ significantly between elective and emergency caesareans, but was significantly lower in the night compared to day.

Zitieren

APA

Moses, A., Ashok, V., Bhukal, I., & Jain, V. (2026). Noise During Anesthetic Induction in Obstetric Operating Rooms: A Prospective Observational Study. Journal of Obstetric Anaesthesia and Critical Care, 16(2), 135-138. https://doi.org/10.4103/joacc.joacc_18_26

Vancouver

Moses A, Ashok V, Bhukal I, Jain V. Noise During Anesthetic Induction in Obstetric Operating Rooms: A Prospective Observational Study. Journal of Obstetric Anaesthesia and Critical Care. 2026;16(2):135-138. doi:10.4103/joacc.joacc_18_26

BibTeX
@article{Moses2026,
  author = {Moses, Abhishek and Ashok, Vighnesh and Bhukal, Ishwar and Jain, Vanita},
  title = {Noise During Anesthetic Induction in Obstetric Operating Rooms: A Prospective Observational Study},
  journal = {Journal of Obstetric Anaesthesia and Critical Care},
  year = {2026},
  volume = {16},
  number = {2},
  pages = {135--138},
  doi = {10.4103/joacc.joacc_18_26}
}