Comparison of Different Models in Calculation of Tumor Control Probability and Normal Tissue Complication Probability in Breast Cancer Radiotherapy
Journal of Medical Signals & Sensors · 2026-10 · 16 (10)
DOI: 10.4103/jmss.jmss_57_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Signals & Sensors, 2026-10. Verfasst von Hayder Tareq und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering and Medical Physics, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
The aim of this study is to compare tumor control probability (TCP) for the planning target volume (PTV) using Poisson, Niemierko, and Zaider-Minerbo models, and normal tissue complication probability (NTCP) for organs at risk (OARs) using Niemierko, Lyman-Kutcher-Burman (LKB) and relative seriality (RS) models.
Methods
Radiotherapy dosimetry data of sixty breast cancer patients were utilized to calculate TCP and NTCP with various models. Patients underwent planning using a 16-slice CT scanner, delivering 50 Gy in 25 fractions using 6 MV photon beam energy and the Monaco treatment planning system (TPS).
Results
Significant differences in TCP were found between Poisson and Zaider-Minerbo models, and between Zaider-Minerbo and equivalent uniform dose (EUD) based models, with no difference between Poisson and EUD-based models. For NTCP, differences were observed between RS model and LKB for heart, spinal cord, and thyroid, as well as between RS model and EUD-based model for the heart, spinal cord and thyroid. LKB and EUD-based models showed differences when considering the lungs as an additional OAR.
Conclusion
Differences among models for calculation TCP and NTCP emphasize the importance of considering specific treatment objectives and patient characteristics in breast cancer radiotherapy planning, ensuring optimized therapeutic outcomes while minimizing adverse effects on healthy tissues.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering and Medical Physics, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
- Department of Medical Physics, Radiation Oncology Center, Vali Asr Hospital, Qom, Iran.
- Department of Medical Physics, Nasiriyah Teaching Hospital, Nasiriyah, Iraq.
Zitieren
APA
Tareq, H., Ghorbani, M., Deevband, M. R., Khosravi, M., & Ali, A. (2026). Comparison of Different Models in Calculation of Tumor Control Probability and Normal Tissue Complication Probability in Breast Cancer Radiotherapy. Journal of Medical Signals & Sensors, 16(10). https://doi.org/10.4103/jmss.jmss_57_25
Vancouver
Tareq H, Ghorbani M, Deevband MR, Khosravi M, Ali A. Comparison of Different Models in Calculation of Tumor Control Probability and Normal Tissue Complication Probability in Breast Cancer Radiotherapy. Journal of Medical Signals & Sensors. 2026;16(10). doi:10.4103/jmss.jmss_57_25
BibTeX
@article{Tareq2026,
author = {Tareq, Hayder and Ghorbani, Mahdi and Deevband, Mohammad Reza and Khosravi, Mehdi and Ali, Abdullah},
title = {Comparison of Different Models in Calculation of Tumor Control Probability and Normal Tissue Complication Probability in Breast Cancer Radiotherapy},
journal = {Journal of Medical Signals & Sensors},
year = {2026},
volume = {16},
number = {10},
doi = {10.4103/jmss.jmss_57_25}
}
EUVIMED