EUVIMEDEUVIMED entdecken
Open Access

An Investigation of Multileaf Collimator Performance Dependence on Gantry Angle Using Machine Log Files

Jeremy L Hughes, Martin A Ebert, Conor K McGarry, Christina E Agnew, Mahsheed Sabet, Pejman Rowshanfarzad

Journal of Medical Physics · 2021-10 · 46 (4) · 300-307

DOI: 10.4103/jmp.jmp_44_21 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Physics, 2021-10. Verfasst von Jeremy L Hughes und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Physics, Mathematics and Computing, University of Western Australia, Perth, WA, Australia. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Quality assurance of linear accelerators (linacs) is an important part of ensuring accurate radiotherapy treatment deliveries. The aim of this study is to investigate the role of gravity on the positional accuracy of multileaf collimator (MLC) leaves during complex radiotherapy treatments on linacs. This investigation is based on the analysis of the machine log files from five different linacs in multiple centers. Materials and Methods: Three main categories of deliveries were considered: Picket fence, volumetric modulated arc therapy (VMAT) (both delivering with continuous gantry rotation), and sliding gap tests delivered at cardinal gantry angles, to determine the error of the MLC in relation to the gantry angle.

Results

Analysis of picket fence tests revealed a dependence of the error upon the gantry angle. For the majority of deliveries, the MLC showed greater error at gantry angles 270 and 90. The errors computed for the cardinal angles for sliding gap tests were all statistically different with greatest error arising at gantry angle 270 and least error at gantry 90. For picket fence, sliding gap, and VMAT cases, MLC errors were dependent on the gantry angle.

Conclusions

The errors in leaf positioning were found to be dependent on the gantry angle. For sliding gap tests, the error was greater at gantry angle 270° and 90° and less when the leaf motion was perpendicular to the force of gravity.

Schlagwörter

Stichwörter der Autor:innen

DynaLogVarianlinaclog filesmultileaf collimator

Autor:innen und Institutionen

  • School of Physics, Mathematics and Computing, University of Western Australia, Perth, WA, Australia.
  • Peter MacCallum Cancer Centre, Melbourne, Melbourne, VIC, Australia.
  • Department of Radiation Oncology, Sir Charles Gairdner Hospital, Perth, WA, Australia.
  • Northern Ireland Cancer Center, Belfast City Hospital, Belfast, United Kingdom.
  • Centre for Cancer Research and Cell Biology, Queen's University, Belfast, United Kingdom.

Zitieren

APA

Hughes, J. L., Ebert, M. A., McGarry, C. K., Agnew, C. E., Sabet, M., & Rowshanfarzad, P. (2021). An Investigation of Multileaf Collimator Performance Dependence on Gantry Angle Using Machine Log Files. Journal of Medical Physics, 46(4), 300-307. https://doi.org/10.4103/jmp.jmp_44_21

Vancouver

Hughes JL, Ebert MA, McGarry CK, Agnew CE, Sabet M, Rowshanfarzad P. An Investigation of Multileaf Collimator Performance Dependence on Gantry Angle Using Machine Log Files. Journal of Medical Physics. 2021;46(4):300-307. doi:10.4103/jmp.jmp_44_21

BibTeX
@article{Hughes2021,
  author = {Hughes, Jeremy L and Ebert, Martin A and McGarry, Conor K and Agnew, Christina E and Sabet, Mahsheed and Rowshanfarzad, Pejman},
  title = {An Investigation of Multileaf Collimator Performance Dependence on Gantry Angle Using Machine Log Files},
  journal = {Journal of Medical Physics},
  year = {2021},
  volume = {46},
  number = {4},
  pages = {300--307},
  doi = {10.4103/jmp.jmp_44_21}
}
Kostenlos starten →