EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Quantitative Analysis of Inter-fractional Setup Errors and Anisotropic Margin Adaptation Using Daily Cone-beam Computed Tomography in Head-and-neck Radiotherapy

Ainain Baba, Obair Yousuf Baba, Abid Ahmad, Misbah Shahid

Journal of Medical Physics · 2026-01 · 51 (1) · 97-102

DOI: 10.4103/jmp.jmp_286_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Physics, online erschienen am 31.03.2026. Verfasst von Ainain Baba und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, University of Kashmir, Srinagar. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To quantify inter-fractional translational and rotational setup errors in head-and-neck cancer patients undergoing radiotherapy with daily cone-beam computed tomography (CBCT) and to derive anisotropic clinical-to-planning target volume (CTV-PTV) margins for improved precision and organ-at-risk (OAR) sparing. Materials and Methods: A retrospective analysis of 1160 daily CBCT scans from 40 patients treated with curative-intent head-and-neck radiotherapy was conducted. Translational (X, Y, and Z) and rotational (pitch, roll, and yaw) displacements were determined by rigid registration of daily CBCT to planning CT. Systematic (Σ) and random (σ) errors were computed, and CTV-PTV margins were derived using the ICRU 62, Stroom, and van Herk margin recipes. The frequency of positional deviations exceeding 3 mm and 5 mm and correlations with clinical factors such as weight loss were analyzed.

Results

Mean systematic errors were 1.5 mm (X), 1.6 mm (Y), and 1.7 mm (Z), while random errors were 0.5 mm, 1.2 mm, and 1.1 mm, respectively. Mean rotational displacements were 0.6° (pitch), 0.5° (roll), and 0.7° (yaw). Margins derived using van Herk’s formula ranged from 4.10 to 5.02 mm. Weight loss showed a moderate correlation with cranio-caudal setup variability ( r = 0.42, P = 0.01). Most fractions remained within 3 mm laterally, with greater deviations observed in the cranio-caudal and antero-posterior directions.

Conclusion

Daily CBCT allows the precise quantification of inter-fractional setup errors and supports direction-specific margin adaptation. Incorporating clinical parameters such as weight loss and rotational deviation into adaptive workflows can enhance treatment precision, OAR sparing, and overall treatment safety in head-and-neck radiotherapy.

Schlagwörter

Stichwörter der Autor:innen

Anisotropic marginscone-beam computed tomographyhead-and-neck cancerorgan-at-risk sparingsetup errorsweight loss

Autor:innen und Institutionen

  • Department of Physics, University of Kashmir, Srinagar.
  • Department of Otorhinolaryngology and Head and Neck Surgery, Government Medical College, Rajouri.
  • Department of Pediatrics and Neonatology, Sher-i-Kashmir Institute of Medical Sciences, Srinagar.
  • Department of Ophthalmology, Acharya Shri Chander College of Medical Sciences and Hospital, Jammu, Jammu and Kashmir, India.

Zitieren

APA

Baba, A., Baba, O. Y., Ahmad, A., & Shahid, M. (2026). Quantitative Analysis of Inter-fractional Setup Errors and Anisotropic Margin Adaptation Using Daily Cone-beam Computed Tomography in Head-and-neck Radiotherapy. Journal of Medical Physics, 51(1), 97-102. https://doi.org/10.4103/jmp.jmp_286_25

Vancouver

Baba A, Baba OY, Ahmad A, Shahid M. Quantitative Analysis of Inter-fractional Setup Errors and Anisotropic Margin Adaptation Using Daily Cone-beam Computed Tomography in Head-and-neck Radiotherapy. Journal of Medical Physics. 2026;51(1):97-102. doi:10.4103/jmp.jmp_286_25

BibTeX
@article{Baba2026,
  author = {Baba, Ainain and Baba, Obair Yousuf and Ahmad, Abid and Shahid, Misbah},
  title = {Quantitative Analysis of Inter-fractional Setup Errors and Anisotropic Margin Adaptation Using Daily Cone-beam Computed Tomography in Head-and-neck Radiotherapy},
  journal = {Journal of Medical Physics},
  year = {2026},
  volume = {51},
  number = {1},
  pages = {97--102},
  doi = {10.4103/jmp.jmp_286_25}
}