EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Evaluation of Residual Liver Motion Using Multiphase Computed Tomography in Stereotactic Body Radiotherapy: A Comparison of Three Motion Management Techniques

P M Jayadevan, Sudesh, N S Shine, K Nithin, S Arathi

Journal of Medical Physics · 2026-01 · 51 (1) · 111-117

DOI: 10.4103/jmp.jmp_252_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Physics, online erschienen am 31.03.2026. Verfasst von P M Jayadevan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Sciences, Banasthali Vidyapith, Banasthali, Rajasthan, India. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The liver is highly susceptible to internal motion during stereotactic body radiotherapy, requiring effective motion management. This study used multiphase computed tomography (MPCT) to assess residual liver movement under deep inspiration breath hold (DIBH), abdominal compression (AC) and free breathing (FB), comparing patient-specific internal target volume (PSITV) and generalized internal target volume (GITV). Materials and Methods: A retrospective analysis of 57 patients with multiple hepatic targets was conducted, where motion management techniques included DIBH ( n = 18), AC ( n = 24), and FB ( n = 15), with each patient undergoing five CT phases (noncontrast, arterial, portal, venous, and delayed). Maximum liver displacements for each patient in the craniocaudal (CC), mediolateral (ML), and anteroposterior (AP) directions were measured to generate PSITVs. The mean displacement across all patients for each technique was taken as the GITV.

Results

Maximum motion occurred in the CC direction, highest in FB (6.73 ± 0.83 mm), followed by AC (5.91 ± 0.50 mm) and DIBH (5.36 ± 0.46 mm). ML and AP motions were similar across techniques: DIBH (2.92 ± 0.33 mm, 3.08 ± 0.38 mm), AC (3.02 ± 0.26 mm, 3.66 ± 0.51 mm), and FB (3.00 ± 0.31 mm, 3.37 ± 0.53 mm). Differences were not statistically significant ( P > 0.3). PSITV was 3.3% larger than GITV in AC, while GITV exceeded PSITV by 2.5% in DIBH.

Conclusion

MPCT identified residual hepatic motion across motion management techniques, highlighting PSITV’s role in improving dosimetric precision and reducing radiation exposure to adjacent organs and normal liver.

Schlagwörter

Stichwörter der Autor:innen

Internal target volumeliver motionmotion managementmultiphase computed tomographystereotactic body radiotherapy

Autor:innen und Institutionen

  • Department of Physical Sciences, Banasthali Vidyapith, Banasthali, Rajasthan, India.
  • Department of Radiation Oncology, Rajagiri Hospital, Aluva, Kerala, India.

Zitieren

APA

Jayadevan, P. M., Sudesh, Shine, N. S., Nithin, K., & Arathi, S. (2026). Evaluation of Residual Liver Motion Using Multiphase Computed Tomography in Stereotactic Body Radiotherapy: A Comparison of Three Motion Management Techniques. Journal of Medical Physics, 51(1), 111-117. https://doi.org/10.4103/jmp.jmp_252_25

Vancouver

Jayadevan PM, Sudesh, Shine NS, Nithin K, Arathi S. Evaluation of Residual Liver Motion Using Multiphase Computed Tomography in Stereotactic Body Radiotherapy: A Comparison of Three Motion Management Techniques. Journal of Medical Physics. 2026;51(1):111-117. doi:10.4103/jmp.jmp_252_25

BibTeX
@article{Jayadevan2026,
  author = {Jayadevan, P M and Sudesh and Shine, N S and Nithin, K and Arathi, S},
  title = {Evaluation of Residual Liver Motion Using Multiphase Computed Tomography in Stereotactic Body Radiotherapy: A Comparison of Three Motion Management Techniques},
  journal = {Journal of Medical Physics},
  year = {2026},
  volume = {51},
  number = {1},
  pages = {111--117},
  doi = {10.4103/jmp.jmp_252_25}
}
Kostenlos starten →