Evaluation of Residual Liver Motion Using Multiphase Computed Tomography in Stereotactic Body Radiotherapy: A Comparison of Three Motion Management Techniques
Journal of Medical Physics · 2026-01 · 51 (1) · 111-117
DOI: 10.4103/jmp.jmp_252_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Physics, online erschienen am 31.03.2026. Verfasst von P M Jayadevan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Sciences, Banasthali Vidyapith, Banasthali, Rajasthan, India. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
The liver is highly susceptible to internal motion during stereotactic body radiotherapy, requiring effective motion management. This study used multiphase computed tomography (MPCT) to assess residual liver movement under deep inspiration breath hold (DIBH), abdominal compression (AC) and free breathing (FB), comparing patient-specific internal target volume (PSITV) and generalized internal target volume (GITV). Materials and Methods: A retrospective analysis of 57 patients with multiple hepatic targets was conducted, where motion management techniques included DIBH ( n = 18), AC ( n = 24), and FB ( n = 15), with each patient undergoing five CT phases (noncontrast, arterial, portal, venous, and delayed). Maximum liver displacements for each patient in the craniocaudal (CC), mediolateral (ML), and anteroposterior (AP) directions were measured to generate PSITVs. The mean displacement across all patients for each technique was taken as the GITV.
Results
Maximum motion occurred in the CC direction, highest in FB (6.73 ± 0.83 mm), followed by AC (5.91 ± 0.50 mm) and DIBH (5.36 ± 0.46 mm). ML and AP motions were similar across techniques: DIBH (2.92 ± 0.33 mm, 3.08 ± 0.38 mm), AC (3.02 ± 0.26 mm, 3.66 ± 0.51 mm), and FB (3.00 ± 0.31 mm, 3.37 ± 0.53 mm). Differences were not statistically significant ( P > 0.3). PSITV was 3.3% larger than GITV in AC, while GITV exceeded PSITV by 2.5% in DIBH.
Conclusion
MPCT identified residual hepatic motion across motion management techniques, highlighting PSITV’s role in improving dosimetric precision and reducing radiation exposure to adjacent organs and normal liver.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physical Sciences, Banasthali Vidyapith, Banasthali, Rajasthan, India.
- Department of Radiation Oncology, Rajagiri Hospital, Aluva, Kerala, India.
Zitieren
APA
Jayadevan, P. M., Sudesh, Shine, N. S., Nithin, K., & Arathi, S. (2026). Evaluation of Residual Liver Motion Using Multiphase Computed Tomography in Stereotactic Body Radiotherapy: A Comparison of Three Motion Management Techniques. Journal of Medical Physics, 51(1), 111-117. https://doi.org/10.4103/jmp.jmp_252_25
Vancouver
Jayadevan PM, Sudesh, Shine NS, Nithin K, Arathi S. Evaluation of Residual Liver Motion Using Multiphase Computed Tomography in Stereotactic Body Radiotherapy: A Comparison of Three Motion Management Techniques. Journal of Medical Physics. 2026;51(1):111-117. doi:10.4103/jmp.jmp_252_25
BibTeX
@article{Jayadevan2026,
author = {Jayadevan, P M and Sudesh and Shine, N S and Nithin, K and Arathi, S},
title = {Evaluation of Residual Liver Motion Using Multiphase Computed Tomography in Stereotactic Body Radiotherapy: A Comparison of Three Motion Management Techniques},
journal = {Journal of Medical Physics},
year = {2026},
volume = {51},
number = {1},
pages = {111--117},
doi = {10.4103/jmp.jmp_252_25}
}
EUVIMED