EUVIMEDEUVIMED entdecken
Crossref

Dosimetric Comparison of Radiation Techniques for Comprehensive Radiation Therapy for Left-Sided Breast Cancer: A Treatment Planning Study

Sajad Ahmad Rather, Muddasir Sharief Banday, Aijaz Ahmad Khan, Shaqul Qamar Wani, Mudasir Ashraf Shah, Samina Mufti

Journal of Marine Medical Society · 2023-07 · 25 (2) · 138-143

DOI: 10.4103/jmms.jmms_158_22 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Marine Medical Society, online erschienen am 21.04.2023. Verfasst von Sajad Ahmad Rather und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The purpose of the study was to determine forward-planned intensity-modulated radiotherapy which improves the sparing of organs at risk (OAR), heart, lungs, and contralateral breast, when compared with multi-field inverse-planned intensity-modulated radiation therapy (RT). The anatomy of the chest wall is curved, which makes it difficult to achieve a homogeneous dose; therefore, it is essential to know the technique by which we can render a better treatment.

Methods

The three-dimensional field-in-field (FIF) technique for radiotherapy is an advanced state-of-the-art method that uses multileaf collimators to generate a homogeneous and conformal dose distribution through segmental subfields. The planning computer tomography (CT) scans of 30 women with left-sided breast cancer previously treated with whole breast RT on an inclined breast board with both arms supported above the head were retrieved. The whole-breast planning target volume (PTV) was defined by clinical markup and contoured on all relevant CT slices as were the OARs. For each patient, two plans were generated using FIF and five-field inverse-planned IMRT, with a prescription dose of 50 Gy in 25 fractions to the whole breast. The mean and maximum doses to the OARs, conformity index, and homogeneity index (HI) of the whole-breast PTV were compared.

Results

The FIF technique significantly reduced the maximum dose of the PTV as well as the mean doses of the heart, ipsilateral lung, contralateral lung, esophagus, and contralateral breast ( P < 0.001 for each). When the organ at risk volumes irradiated with 10, 20, 30, and 40 Gy were compared, the results were in favor of the FIF technique. The volume receiving

Zitieren

APA

Rather, S. A., Banday, M. S., Khan, A. A., Wani, S. Q., Shah, M. A., & Mufti, S. (2023). Dosimetric Comparison of Radiation Techniques for Comprehensive Radiation Therapy for Left-Sided Breast Cancer: A Treatment Planning Study. Journal of Marine Medical Society, 25(2), 138-143. https://doi.org/10.4103/jmms.jmms_158_22

Vancouver

Rather SA, Banday MS, Khan AA, Wani SQ, Shah MA, Mufti S. Dosimetric Comparison of Radiation Techniques for Comprehensive Radiation Therapy for Left-Sided Breast Cancer: A Treatment Planning Study. Journal of Marine Medical Society. 2023;25(2):138-143. doi:10.4103/jmms.jmms_158_22

BibTeX
@article{Rather2023,
  author = {Rather, Sajad Ahmad and Banday, Muddasir Sharief and Khan, Aijaz Ahmad and Wani, Shaqul Qamar and Shah, Mudasir Ashraf and Mufti, Samina},
  title = {Dosimetric Comparison of Radiation Techniques for Comprehensive Radiation Therapy for Left-Sided Breast Cancer: A Treatment Planning Study},
  journal = {Journal of Marine Medical Society},
  year = {2023},
  volume = {25},
  number = {2},
  pages = {138--143},
  doi = {10.4103/jmms.jmms_158_22}
}