EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Influence of abutment design on the fit of computer-aided design and computer-aided manufacturing (CAD-CAM) fabricated lithium disilicate copings: An in vitro study

Leonardo Lins, Cristiana Licurci, Carolina Chaves Pinto, Cristiane Borsodi, Antonio Canabarro

Journal of Indian Society of Periodontology · 2026-07 · 30 (3) · 409-414

DOI: 10.4103/jisp.jisp_507_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Indian Society of Periodontology, online erschienen am 29.10.2026. Verfasst von Leonardo Lins und 4 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The fit of cement-retained implant restorations is important for prosthetic longevity and peri-implant health. This in vitro study evaluated and compared the internal and marginal fit of computer-aided design and computer-aided manufacturing (CAD/CAM) lithium disilicate copings (LDUCs) fabricated on three Cone Morse titanium abutment designs: anatomic, lateral anatomic, and universal. Materials and Methods: Thirty-six abutments ( n = 12 per design) were scanned, and LDUCs were fabricated using the Ceramill system. After standardized cementation, specimens were sectioned in buccal–palatal and mesial–distal directions. Internal gaps were measured microscopically at ×100 to ×200 magnification at angular, linear, and occlusal regions. Marginal adaptation was assessed as marginal discrepancy and absolute marginal discrepancy.

Results

Statistically significant differences were observed among abutment designs ( P < 0.05). The anatomic design showed the smallest internal and marginal gaps, whereas the lateral anatomic and universal designs exhibited larger discrepancies, particularly in the occlusal and marginal areas. No significant laboratory effect was detected.

Conclusions

Within the limitations of this in vitro study, abutment geometry significantly influenced the internal and marginal fit of CAD/CAM lithium disilicate restorations. The anatomic design demonstrated the most favorable adaptation among the evaluated groups. However, further in vivo investigations and randomized clinical trials are necessary to determine whether these laboratory findings translate into improved long-term clinical performance.

Zitieren

APA

Lins, L., Licurci, C., Pinto, C. C., Borsodi, C., & Canabarro, A. (2026). Influence of abutment design on the fit of computer-aided design and computer-aided manufacturing (CAD-CAM) fabricated lithium disilicate copings: An in vitro study. Journal of Indian Society of Periodontology, 30(3), 409-414. https://doi.org/10.4103/jisp.jisp_507_25

Vancouver

Lins L, Licurci C, Pinto CC, Borsodi C, Canabarro A. Influence of abutment design on the fit of computer-aided design and computer-aided manufacturing (CAD-CAM) fabricated lithium disilicate copings: An in vitro study. Journal of Indian Society of Periodontology. 2026;30(3):409-414. doi:10.4103/jisp.jisp_507_25

BibTeX
@article{Lins2026,
  author = {Lins, Leonardo and Licurci, Cristiana and Pinto, Carolina Chaves and Borsodi, Cristiane and Canabarro, Antonio},
  title = {Influence of abutment design on the fit of computer-aided design and computer-aided manufacturing (CAD-CAM) fabricated lithium disilicate copings: An in vitro study},
  journal = {Journal of Indian Society of Periodontology},
  year = {2026},
  volume = {30},
  number = {3},
  pages = {409--414},
  doi = {10.4103/jisp.jisp_507_25}
}
Kostenlos starten →