EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-SA 4.0

Comparison of the antibacterial efficacy of 810 nm diode laser and photodynamic therapy in reducing microbial flora in patients with peri-implant mucositis – An in vivo study

Poonam Siwach, Reshu Sanan, Abhishek Nagpal, Omkar Krishna Shetty, Amit Bhardwaj, Mukesh Sharma

The Journal of Indian Prosthodontic Society · 2025

DOI: 10.4103/jips.jips_64_24 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Indian Prosthodontic Society, 2025. Verfasst von Poonam Siwach und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Faculty of Dental Sciences, SGT University, Gurugram, Haryana, India. Hauptthemen laut MEDLINE: Photochemotherapy, Lasers, Semiconductor, Tolonium Chloride, Photosensitizing Agents. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

The aim of this study was to investigate and compare the antimicrobial effects of an 810-nanometer diode laser, utilizing or not utilizing toluidine blue as a photosensitizer, in the management of peri-implant mucositis. Settings and Design: The present study was carried out in 30 implant sites in 15 patients with peri-implant mucositis with a specific inclusion and exclusion criteria. 15 sites were treated utilizing a diode laser (control group) and 15 with photodynamic therapy (test group) in a split-mouth format. Materials and Methods: Samples were taken from the gingival sulcus with the help of plastic curettes from control and test sites both at baseline and at 3 months for microbiological analysis. Statistical Analysis Used: Shapiro-Wilk Test was used to check deviation from normality. Wilcoxon signed-rank test was used to analyse the two dependent groups.

Results

Intragroup comparison was found to be statistically significant when compared at baseline and at 3 months in the photodynamic ( P = 0.001) and diode laser groups ( P = 0.001), respectively. No statistically significant reduction in bacterial count was found at baseline ( P = 0.1) and at 3 months ( P = 0.5) when the diode laser group and photodynamic group were compared with each other (intergroup).

Conclusion

Within the limitations of the study, it can be concluded that there is a definitive reduction in pathogenic bacteria with both interventions and PDT offers clinically visible benefits in the treatment of peri-implant mucositis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotochemotherapyLasers, SemiconductorTolonium ChloridePhotosensitizing AgentsPeri-ImplantitisHumansFemaleMaleMiddle AgedStomatitisAdultBacterial Load

Substanzen

Tolonium ChloridePhotosensitizing Agents

Autor:innen und Institutionen

  • Department of Prosthodontics, Faculty of Dental Sciences, SGT University, Gurugram, Haryana, India.
  • Department of Periodontics, Faculty of Dental Sciences, SGT University, Gurugram, Haryana, India.
  • Department of Microbiology, Faculty of Medicine and Health Sciences, SGT University, Gurugram, Haryana, India.

Zitieren

APA

Siwach, P., Sanan, R., Nagpal, A., Shetty, O. K., Bhardwaj, A., & Sharma, M. (2025). Comparison of the antibacterial efficacy of 810 nm diode laser and photodynamic therapy in reducing microbial flora in patients with peri-implant mucositis – An in vivo study. The Journal of Indian Prosthodontic Society. https://doi.org/10.4103/jips.jips_64_24

Vancouver

Siwach P, Sanan R, Nagpal A, Shetty OK, Bhardwaj A, Sharma M. Comparison of the antibacterial efficacy of 810 nm diode laser and photodynamic therapy in reducing microbial flora in patients with peri-implant mucositis – An in vivo study. The Journal of Indian Prosthodontic Society. 2025. doi:10.4103/jips.jips_64_24

BibTeX
@article{Siwach2025,
  author = {Siwach, Poonam and Sanan, Reshu and Nagpal, Abhishek and Shetty, Omkar Krishna and Bhardwaj, Amit and Sharma, Mukesh},
  title = {Comparison of the antibacterial efficacy of 810 nm diode laser and photodynamic therapy in reducing microbial flora in patients with peri-implant mucositis – An in vivo study},
  journal = {The Journal of Indian Prosthodontic Society},
  year = {2025},
  doi = {10.4103/jips.jips_64_24}
}
Kostenlos starten →