A comparative in vitro analysis of various temporization materials with respect to pulp chamber temperature changes during polymerization
The Journal of Indian Prosthodontic Society · 2024
DOI: 10.4103/jips.jips_492_23 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Indian Prosthodontic Society, 2024. Verfasst von Sneha Bharadwaj und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Faculty in Clove Dental, New Delhi, India. Hauptthemen laut MEDLINE: Polymerization. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Aim
(1) To compare the temperature rise in the pulp chamber with different resin materials used for making provisional fixed partial dentures in anterior and posterior region while using Polyvinylsiloxane impression materials as matrix. (2) To identify a superior provisionalization material based on the amount of heat dissipated suitable for anterior and posterior provisional fixed partial denture fabrication. Settings and Design: Temporary crowns and bridges are integral to Fixed Prosthodontics. It has been observed that conventional fixed prosthesis temporisation materials release heat due to the exothermic polymerisation reaction. When such a provisional material is directly let to set on a vital tooth, the heat transfer causes irreversible changes in the pulp tissue depending of the degree of change. Hence, this study observes amount of heat generation in various materials during temporisation procedure, by simulating similar conditions. Materials and Methods: Two Models were fabricated, one simulating missing lateral incisor (Model A) and another simulating missing first molar (Model B). Intact maxillary central incisors and canine for Model A and intact mandibular Second Premolar and Second Molar were selected to act as abutments. These abutment teeth were fitted with the tip of a K-type Thermocouple inside their pulp chambers and these were connected to a digital thermometer. Five temporisation materials were chosen for fabrication of temporary crowns through Direct technique. (1) polymethy methacrylate (Self Cure acrylic), (2) bisacryl composite (Protemp 4), (3) visible light cure urethane dimethacrylate (Revotec LC), (4) barium glass and fumed silica infused methacrylate (Dentsply Integrity) and (5)nano-hybrid composite (VOCO Structur 3). Ten observations were made for each provisional material on each model. During each observation, temperature rise was recorded at 30s interval from the time of application, through the peak and till a decrease in temperature is observed. Polyvinyl siloxane was used as matrix for all except light cure resin, where polypropylene sheet was used. Statistical Analysis Used: Anova test used for statistical.
Results
ANOVA test revealed that there was a significant difference in the temperature changes associated with the provisional restorative materials used. Among the five, polymethy methacrylate (self cure resin) showed the maximum rise in temperature, followed by bisacryl composite (Protemp 4), visible light cure urethane dimethacrylate (Revotec LC), barium glass and fumed silica infused methacrylate (Dentsply Integrity) and nano-hybrid composite (VOCO Structur 3). There was no comparable difference between Model A and B but an overall reduction of temperature rise was observed in model B.
Conclusion
VOCO Structur 3 showed the least temperature rise in the pulp chamber, and overall temperature rise was less for model B which can be attributed to the residual dentin thickness.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics, Faculty in Clove Dental, New Delhi, India.
- Department of Prosthodontics, Institute of Dental Sciences, Siksha 'O' Anusandhan Deemed to be University, Bhubaneswar, Odisha, India.
- Department of Community Dentistry, Institute of Dental Sciences, Siksha 'O' Anusandhan Deemed to be University, Bhubaneswar, Odisha, India.
Zitieren
APA
Bharadwaj, S., Choudhury, G. K., Mohapatra, A., Panda, S., & Dhar, U. (2024). A comparative in vitro analysis of various temporization materials with respect to pulp chamber temperature changes during polymerization. The Journal of Indian Prosthodontic Society. https://doi.org/10.4103/jips.jips_492_23
Vancouver
Bharadwaj S, Choudhury GK, Mohapatra A, Panda S, Dhar U. A comparative in vitro analysis of various temporization materials with respect to pulp chamber temperature changes during polymerization. The Journal of Indian Prosthodontic Society. 2024. doi:10.4103/jips.jips_492_23
BibTeX
@article{Bharadwaj2024,
author = {Bharadwaj, Sneha and Choudhury, Gopal Krishna and Mohapatra, Abhilash and Panda, Sangram and Dhar, Upasana},
title = {A comparative in vitro analysis of various temporization materials with respect to pulp chamber temperature changes during polymerization},
journal = {The Journal of Indian Prosthodontic Society},
year = {2024},
doi = {10.4103/jips.jips_492_23}
}