Predictors of patient dissatisfaction with ceramic veneers: A matched case–control study
The Journal of Indian Prosthodontic Society · 2026-01 · 26 (1) · 96-101
DOI: 10.4103/jips.jips_402_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Indian Prosthodontic Society, online erschienen am 01.01.2026. Verfasst von Sagar J Abichandani und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Private Practice, Mumbai, Maharashtra, India. Hauptthemen laut MEDLINE: Dental Veneers, Patient Satisfaction, Ceramics, Esthetics, Dental. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Aim
To assess the association between mock-up technique (chairside bis-acryl vs digitally fabricated 3D-printed) and shade-matching protocol (chairside visual vs laboratory-assisted/digital) with patient-initiated esthetic dissatisfaction resulting in refund or retreatment within 12 months of veneer delivery. Settings and Design: Single-center, 1:1 matched case–control study (23 pairs; n = 46) in a private prosthodontic practice. Materials and Methods: Exposures were chairside bis-acryl versus digitally fabricated 3D-printed mock-ups and chairside visual versus laboratory-assisted/digital shade matching. The primary outcome was patient-initiated esthetic dissatisfaction within 12 months resulting in refund or retreatment; refund-only and retreatment-only outcomes were prespecified as exploratory. Statistical Analysis Used: Primary analysis used exact conditional methods for matched pairs (McNemar) with exact 95% confidence intervals; in the presence of separation, the exact lower confidence bound was reported without continuity corrections. A supportive multivariable unconditional logistic regression adjusted for age, sex, exact number of units, arch, and cost tier, and E-values were calculated to assess robustness to unmeasured confounding.
Results
Chairside mock-ups and chairside-only shade selection were more frequent in cases than controls. The matched odds ratio (OR) for chairside versus digitally fabricated mock-ups was ∞ (exact lower 95% confidence interval ≥2.51; P = 0.0010), and for chairside versus laboratory-assisted/digital shade matching was 6.00 (95% confidence interval 1.34–55.20; P = 0.0129). In the supportive adjusted model, the ORs were 5.87 (95% confidence interval 1.59–21.66; P = 0.008) for mock-up technique and 4.41 (1.26–15.42; P = 0.021) for shade protocol; corresponding E-values were 11.48, 11.22, and 8.29, respectively.
Conclusion
Within the limitations of a retrospective, single-center design and modest sample size, chairside bis-acryl mock-ups and chairside-only shade matching were associated with higher odds of early esthetic dissatisfaction leading to refund or retreatment. Adoption of standardized digital workflows with digitally designed/3D-printed mock-ups and calibrated shade protocols is recommended as a clinical quality-assurance measure to mitigate this risk.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, Private Practice, Mumbai, Maharashtra, India.
- Department of General Dentistry, Private Practice, Mumbai, Maharashtra, India.
Zitieren
APA
Abichandani, S. J., & Dutta, A. (2026). Predictors of patient dissatisfaction with ceramic veneers: A matched case–control study. The Journal of Indian Prosthodontic Society, 26(1), 96-101. https://doi.org/10.4103/jips.jips_402_25
Vancouver
Abichandani SJ, Dutta A. Predictors of patient dissatisfaction with ceramic veneers: A matched case–control study. The Journal of Indian Prosthodontic Society. 2026;26(1):96-101. doi:10.4103/jips.jips_402_25
BibTeX
@article{Abichandani2026,
author = {Abichandani, Sagar J and Dutta, Aneendita},
title = {Predictors of patient dissatisfaction with ceramic veneers: A matched case–control study},
journal = {The Journal of Indian Prosthodontic Society},
year = {2026},
volume = {26},
number = {1},
pages = {96--101},
doi = {10.4103/jips.jips_402_25}
}
EUVIMED