Decision-making Using Morphometry of Urethral Plate and Glans Width in Selecting Distal Hypospadias Repair Technique – A Systematic Review
Journal of Indian Association of Pediatric Surgeons · 2026-11 · 31 (6) · 897-906
DOI: 10.4103/jiaps.jiaps_252_26 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Journal of Indian Association of Pediatric Surgeons, online erschienen am 15.10.2026. Verfasst von Vikesh Agrawal und 1 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
A BSTRACT The urethral plate (UP) and glans width (GW) are important determinants of outcomes following distal hypospadias repair, but considerable variability exists in their measurement and interpretation. We conducted a systematic review according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 statement, searching PubMed/MEDLINE, Embase, Cochrane CENTRAL, Web of Science, Scopus, and Google Scholar for studies published between January 2004 and December 2024 reporting UP and/or GW measurements in children undergoing hypospadias repair. Two reviewers independently extracted the data. To address variability in UP measurement, we standardized assessment at the narrowest glanular segment, designated the “B point,” to define the B-Urethral Plate (B-UP) measurement. Fourteen studies involving 1348 patients were included. Mean reported UP width ranged from 4.8 ± 1.3 mm to 7.3 ± 0.5 mm, while mean GW ranged from 9.5 ± 1.6 mm to 10.4 ± 2.2 mm. Reported complication rates ranged from 0% to 35% and appeared higher with narrower UPs (14 mm, Thiersch–Duplay repair; B-UP 6–8 mm with GW ≥14 mm, tubularized incised plate (TIP) repair; B-UP 14 mm, grafted TIP; and B-UP
Zitieren
APA
Agrawal, V., & Babu, R. (2026). Decision-making Using Morphometry of Urethral Plate and Glans Width in Selecting Distal Hypospadias Repair Technique – A Systematic Review. Journal of Indian Association of Pediatric Surgeons, 31(6), 897-906. https://doi.org/10.4103/jiaps.jiaps_252_26
Vancouver
Agrawal V, Babu R. Decision-making Using Morphometry of Urethral Plate and Glans Width in Selecting Distal Hypospadias Repair Technique – A Systematic Review. Journal of Indian Association of Pediatric Surgeons. 2026;31(6):897-906. doi:10.4103/jiaps.jiaps_252_26
BibTeX
@article{Agrawal2026,
author = {Agrawal, Vikesh and Babu, Ramesh},
title = {Decision-making Using Morphometry of Urethral Plate and Glans Width in Selecting Distal Hypospadias Repair Technique – A Systematic Review},
journal = {Journal of Indian Association of Pediatric Surgeons},
year = {2026},
volume = {31},
number = {6},
pages = {897--906},
doi = {10.4103/jiaps.jiaps_252_26}
}
EUVIMED