EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Comparison of T2* and Native T1 and T2 Mapping in Patients with Hemolytic Anemia

Rosh Varghese Georgy, Elizabeth Joseph, Aparna Irodi, Binita Riya Chacko, Leena Robinson Vimala, Roshan Samuel Livingstone

Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging · 2026-01 · 10 (1) · 1-7

DOI: 10.4103/jiae.jiae_83_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging, online erschienen am 23.04.2026. Verfasst von Rosh Varghese Georgy und 5 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate myocardial iron quantification is essential for preventing iron overload cardiomyopathy, optimizing chelation therapy, and monitoring treatment response in patients with hemolytic anemias. While T2* is an established noninvasive technique for assessing cardiac iron overload (CIO), native T1 and T2 mapping are emerging parametric methods. The aim of this study was to evaluate native myocardial T1, T2, and T2* values in patients with hemolytic anemia. Materials and Methods: Forty consecutive patients with hemolytic anemia were evaluated using a 1.5 T magnetic resonance imaging scanner (Siemens Magnetom Avanto fit). Ventricular short-axis cine steady-state free precession images were acquired, along with single midventricular short-axis slices for T2*, T1, and T2 mapping. T1 and T2 measurements were obtained from automated parametric maps (Siemens MyoMaps) using manually drawn large midmyocardial regions of interest (>20 pixels). Siemens Syngo Workstation was used to calculate left ventricular function.

Results

Cardiac T2* demonstrated a strong positive correlation with both native T1 ( r = 0.821) and T2 mapping ( r = 0.828). However, 30% of the study population had normal T2* values despite reduced T1 (

Zitieren

APA

Georgy, R. V., Joseph, E., Irodi, A., Chacko, B. R., Vimala, L. R., & Livingstone, R. S. (2026). Comparison of T2* and Native T1 and T2 Mapping in Patients with Hemolytic Anemia. Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging, 10(1), 1-7. https://doi.org/10.4103/jiae.jiae_83_25

Vancouver

Georgy RV, Joseph E, Irodi A, Chacko BR, Vimala LR, Livingstone RS. Comparison of T2* and Native T1 and T2 Mapping in Patients with Hemolytic Anemia. Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging. 2026;10(1):1-7. doi:10.4103/jiae.jiae_83_25

BibTeX
@article{Georgy2026,
  author = {Georgy, Rosh Varghese and Joseph, Elizabeth and Irodi, Aparna and Chacko, Binita Riya and Vimala, Leena Robinson and Livingstone, Roshan Samuel},
  title = {Comparison of T2* and Native T1 and T2 Mapping in Patients with Hemolytic Anemia},
  journal = {Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging},
  year = {2026},
  volume = {10},
  number = {1},
  pages = {1--7},
  doi = {10.4103/jiae.jiae_83_25}
}
Kostenlos starten →