EUVIMEDEUVIMED entdecken
Crossref

Reproducibility of Echocardiography in Assessing Left Atrial Reservoir Function in Rheumatic Mitral Valve Disease

Mona A. Elsaidy, Mohamed A. Abdalaal, Ayman A. Elsheikh, Sarah Elsharkawi

Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging · 2019

DOI: 10.4103/jiae.jiae_13_19 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging, 2019. Verfasst von Mona A. Elsaidy und 3 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Although abnormal left atrial (LA) reservoir function had been associated with clinical events in patients with mitral valve disease, its routine assessment is not performed due to inaccuracies and difficult time-consuming measurements.

Aim

The aim was to study the feasibility and reproducibility of different echocardiographic parameters for LA assessment in patients with rheumatic mitral valve disease.

Methods

Two hundred and fifty-nine patients with mitral valve disease underwent full echocardiographic examination. LA reservoir function was measured by two-dimensional (2D) volumes, 3D volumes, and global longitudinal strain (LA GLS). LA GLS, volumes, and total left atrial emptying fraction values were repeated to obtain the intra- and interobserver variabilities. The latter was performed between a nonexpert and two expert examiners.

Results

3D echocardiography was highly feasible in assessing LA function, feasibility was 94%, and was performed in the shortest time (1.3 ± 0.4, ANOVA, P < 0.0001). All LA 3D measurements showed excellent intraobserver and interobserver reproducibility between the two expert readers; coefficient of variation (CV) was 7% and 8%, respectively, for LA maximal volume index (LAVImax). Although CV for interobserver variability between the expert and nonexpert readers was 12% for 3D minimal LAVI (LAVImin), assessment of 2D LA volumes had the lowest reproducibility; CV was 15% for LAVImin.

Conclusion

3-d echocardiography assessment of LA volumes and function in patients with rheumatic heart disease is highly feasible and reproducible; it is easy to learn and can be easily performed by nonexperts.

Zitieren

APA

Elsaidy, M. A., Abdalaal, M. A., Elsheikh, A. A., & Elsharkawi, S. (2019). Reproducibility of Echocardiography in Assessing Left Atrial Reservoir Function in Rheumatic Mitral Valve Disease. Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging. https://doi.org/10.4103/jiae.jiae_13_19

Vancouver

Elsaidy MA, Abdalaal MA, Elsheikh AA, Elsharkawi S. Reproducibility of Echocardiography in Assessing Left Atrial Reservoir Function in Rheumatic Mitral Valve Disease. Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging. 2019. doi:10.4103/jiae.jiae_13_19

BibTeX
@article{Elsaidy2019,
  author = {Elsaidy, Mona A. and Abdalaal, Mohamed A. and Elsheikh, Ayman A. and Elsharkawi, Sarah},
  title = {Reproducibility of Echocardiography in Assessing Left Atrial Reservoir Function in Rheumatic Mitral Valve Disease},
  journal = {Journal of The Indian Academy of Echocardiography & Cardiovascular Imaging},
  year = {2019},
  doi = {10.4103/jiae.jiae_13_19}
}
Kostenlos starten →