EUVIMEDEUVIMED entdecken
Open Access

C1-C2 arthroplasty for craniovertebral junction instability

Pravin Salunke, Madhivanan Karthigeyan, Manoj Kumar Kodigudla, Amey V Kelkar, Vijay K Goel

Journal of Craniovertebral Junction and Spine · 2022-04 · 13 (2) · 159-162

DOI: 10.4103/jcvjs.jcvjs_33_22 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Craniovertebral Junction and Spine, 2022-04. Verfasst von Pravin Salunke und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Postgraduate Institute of Medical Education and Research, Chandigarh, India. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The atlantoaxial complex contributes to significant neck movements, especially the axial rotation. Its instability is currently treated with various C1-C2 fusion techniques. This however, considerably hampers the neck movements and affects the quality of life; a C1-C2 motion preserving arthroplasty could potentially overcome this drawback.

Objectives

We evaluate the range of motion (ROM) of lateral C1-C2 artificial joints in cadaveric models. Materials and Methods: This is an in vitro cadaveric biomechanical study. After C1-C2 arthroplasty through a posterior approach, the C1-C2 ROM was tested in 4 fresh-frozen human cadaveric specimens, before and after destabilization.

Results

The mean axial rotation demonstrated after the placement of C1-C2 joint implants was 15.46 degrees on the right and 16.03 degrees on the left side; the prosthesis provided stability, with 46% of the baseline C1-C2 axial rotation on either side. The ROM achieved in the other axes was less compared with that of intact specimens. To initiate rotation, a higher moment of 1.5 Nm was required in the presence of joint implants compared to 0.5 NM in unimplanted specimens.

Conclusions

In our preliminary ROM evaluation, the C1-C2 arthroplasty appears to be stable and provides about half of the range of atlantoaxial rotation. It has the potential for joint motion preservation in the treatment of atlantoaxial instability resulting from lateral C1-C2 joint pathologies.

Schlagwörter

Stichwörter der Autor:innen

Artificial jointsC1-C2atlantoaxialbiomechanicscraniovertebral junctionkinematicsneck rotationprosthesis

Autor:innen und Institutionen

  • Department of Neurosurgery, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
  • Department of Bioengineering, Engineering Center for Orthopaedic Research Excellence, The University of Toledo, Toledo, Ohio, USA.

Zitieren

APA

Salunke, P., Karthigeyan, M., Kodigudla, M. K., Kelkar, A. V., & Goel, V. K. (2022). C1-C2 arthroplasty for craniovertebral junction instability. Journal of Craniovertebral Junction and Spine, 13(2), 159-162. https://doi.org/10.4103/jcvjs.jcvjs_33_22

Vancouver

Salunke P, Karthigeyan M, Kodigudla MK, Kelkar AV, Goel VK. C1-C2 arthroplasty for craniovertebral junction instability. Journal of Craniovertebral Junction and Spine. 2022;13(2):159-162. doi:10.4103/jcvjs.jcvjs_33_22

BibTeX
@article{Salunke2022,
  author = {Salunke, Pravin and Karthigeyan, Madhivanan and Kodigudla, Manoj Kumar and Kelkar, Amey V and Goel, Vijay K},
  title = {C1-C2 arthroplasty for craniovertebral junction instability},
  journal = {Journal of Craniovertebral Junction and Spine},
  year = {2022},
  volume = {13},
  number = {2},
  pages = {159--162},
  doi = {10.4103/jcvjs.jcvjs_33_22}
}
Kostenlos starten →