Inside–outside occipital screw technique for failed occipitocervical fusion: A salvage strategy in patients with thin occipital bone
Journal of Craniovertebral Junction and Spine · 2026-11 · 17 (6) · 643-648
DOI: 10.4103/jcvjs.jcvjs_156_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Craniovertebral Junction and Spine, online erschienen am 20.11.2026. Verfasst von Serdar Solmaz und 6 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Failure of occipital fixation remains a significant challenge in occipitocervical fusion (OCF), particularly in patients with reduced occipital bone thickness. The inside–outside (I/O) occipital screw technique has been proposed as an alternative fixation method that engages the inner cortical table to improve screw purchase. Materials and Methods: We retrospectively reviewed five patients who underwent revision occipitocervical stabilization using the I/O occipital screw technique following failure of primary constructs due to occipital screw pullout. Clinical characteristics, imaging findings, occipital bone thickness, surgical details, and outcomes were analyzed. Mean occipital bone thickness was 8.1 mm (range: 7.5–9.6 mm) and mean follow-up was 31.6 months (range: 7–48 months).
Results
Revision surgery was successfully performed in all patients while preserving existing cervical instrumentation. No intraoperative or postoperative complications were observed. All constructs remained stable throughout follow-up without hardware failure. Clinical symptoms improved or remained stable in all patients. One patient died during follow-up from pneumonia unrelated to the procedure.
Conclusions
The I/O occipital screw technique appears to be a safe and effective salvage option for failed OCF due to occipital screw pullout. Reduced occipital bone thickness may contribute to failure of conventional fixation, and the I/O technique may offer a biomechanical advantage in such cases. It may also represent a potential primary fixation strategy in selected patients with thin occipital bone, although larger studies are needed to further define its indications and long-term outcomes.
Zitieren
APA
Solmaz, S., Gulsever, C. I., Eray, H. A., Büyüktepe, M., Solmaz, F. G. Ş., Doğan, I., & Caglar, Y. S. (2026). Inside–outside occipital screw technique for failed occipitocervical fusion: A salvage strategy in patients with thin occipital bone. Journal of Craniovertebral Junction and Spine, 17(6), 643-648. https://doi.org/10.4103/jcvjs.jcvjs_156_26
Vancouver
Solmaz S, Gulsever CI, Eray HA, Büyüktepe M, Solmaz FGŞ, Doğan I, et al. Inside–outside occipital screw technique for failed occipitocervical fusion: A salvage strategy in patients with thin occipital bone. Journal of Craniovertebral Junction and Spine. 2026;17(6):643-648. doi:10.4103/jcvjs.jcvjs_156_26
BibTeX
@article{Solmaz2026,
author = {Solmaz, Serdar and Gulsever, Cafer Ikbal and Eray, Halit Anıl and Büyüktepe, Murat and Solmaz, Firdevs Gonca Şaşal and Doğan, Ihsan and Caglar, Yusuf Sukru},
title = {Inside–outside occipital screw technique for failed occipitocervical fusion: A salvage strategy in patients with thin occipital bone},
journal = {Journal of Craniovertebral Junction and Spine},
year = {2026},
volume = {17},
number = {6},
pages = {643--648},
doi = {10.4103/jcvjs.jcvjs_156_26}
}
EUVIMED