Sponging and drying technique - To seal clear corneal incisions in phacoemulsification surgery
Journal of Clinical Ophthalmology and Research · 2026-10 · 14 (4) · 513-516
DOI: 10.4103/jcor.jcor_306_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Ophthalmology and Research, online erschienen am 18.11.2026. Verfasst von Harshul Kumar Tak. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
The author describes a novel technique of using polyvinyl alcohol (PVA) sponge for sponging and drying to seal clear corneal incisions which leak even after conventional stromal hydration at the end of phacoemulsification surgery. Using PVA sponge, fluid is absorbed from leaking incision so that both lips of incision get apposed. Once two lips get apposed, it is left for drying for 1–2 min. By capillary action of sponging excess fluid from incision tunnel and drying for 1–2 min, sealing of the leaking incisions take place which is confirmed by negative Seidel’s test using trypan blue dye.
Zitieren
APA
Tak, H. K. (2026). Sponging and drying technique - To seal clear corneal incisions in phacoemulsification surgery. Journal of Clinical Ophthalmology and Research, 14(4), 513-516. https://doi.org/10.4103/jcor.jcor_306_26
Vancouver
Tak HK. Sponging and drying technique - To seal clear corneal incisions in phacoemulsification surgery. Journal of Clinical Ophthalmology and Research. 2026;14(4):513-516. doi:10.4103/jcor.jcor_306_26
BibTeX
@article{Tak2026,
author = {Tak, Harshul Kumar},
title = {Sponging and drying technique - To seal clear corneal incisions in phacoemulsification surgery},
journal = {Journal of Clinical Ophthalmology and Research},
year = {2026},
volume = {14},
number = {4},
pages = {513--516},
doi = {10.4103/jcor.jcor_306_26}
}