Comparison of Noncontact Forehead Infrared Thermometer with Digital Axillary Thermometer in Newborns in Low- and Middle-income Countries

Sreetama Das, Somnath Pal, Moumita Ghosh

Journal of Clinical Neonatology · 2025-01 · 14 (1) · 1-8

DOI: 10.4103/jcn.jcn_64_24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Neonatology, online erschienen am 14.02.2025. Verfasst von Sreetama Das und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Noncontact forehead infrared thermometry can be a rapid and developmentally supportive measurement of temperature in newborns. This study compared forehead infrared temperature with digital axillary temperature in newborns in the setting of a developing country. Materials and Methods: An agreement study was conducted from March 2024 to May 2024 in a tertiary neonatal unit of India. A maximum acceptable limit of ±0.5° between 2 methods was chosen. Agreement between both readings was assessed by Bland–Altman analysis. A multiple linear regression model was built to predict factors affecting the difference between both methods and validated using bootstrap samples with replacement. Revised Premature Infant Pain Profile (PIPP) was used for documenting pain attributed by each method and the difference was assessed using paired t -test.

Results

Three hundred temperature records were collected from 181 infants. Mean difference between 2 methods was −0.004°C signifying the absence of systematic bias. Upper and lower limit of agreements was 0.61°C and −0.62°C. There was a proportional bias with forehead temperature underestimating axillary temperature above 37.5°C, which increased further while using warmer. Infrared thermometer showed good accuracy in detecting hyperthermia (area under curve 0.964, P < 0.001). Revised PIPP score was higher in digital axillary thermometry ( P < 0.05).

Conclusion

Forehead infrared temperatures were found to be distributed within ±0.6°C of the axillary temperatures. It can be used as a screening tool for hyperthermia in newborns in developing countries.

Zitieren

APA

Das, S., Pal, S., & Ghosh, M. (2025). Comparison of Noncontact Forehead Infrared Thermometer with Digital Axillary Thermometer in Newborns in Low- and Middle-income Countries. Journal of Clinical Neonatology, 14(1), 1-8. https://doi.org/10.4103/jcn.jcn_64_24

Vancouver

Das S, Pal S, Ghosh M. Comparison of Noncontact Forehead Infrared Thermometer with Digital Axillary Thermometer in Newborns in Low- and Middle-income Countries. Journal of Clinical Neonatology. 2025;14(1):1-8. doi:10.4103/jcn.jcn_64_24

BibTeX
@article{Das2025,
  author = {Das, Sreetama and Pal, Somnath and Ghosh, Moumita},
  title = {Comparison of Noncontact Forehead Infrared Thermometer with Digital Axillary Thermometer in Newborns in Low- and Middle-income Countries},
  journal = {Journal of Clinical Neonatology},
  year = {2025},
  volume = {14},
  number = {1},
  pages = {1--8},
  doi = {10.4103/jcn.jcn_64_24}
}
Kostenlos starten →