Clinical outcomes and patient-reported benefits of an active bone conduction implant in single-sided deafness: A prospective study
Journal of Clinical Sciences · 2026-04 · 23 (2) · 70-76
DOI: 10.4103/jcls.jcls_231_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Sciences, online erschienen am 25.05.2026. Verfasst von Piotr Henryk Skarzynski und 3 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Single-sided deafness (SSD) is defined as complete deafness in one ear while the other ear has normal hearing, up to mild hearing loss. Patients with SSD experience various hearing difficulties, including problems locating the source of a sound, its intensity, reduced spatial awareness, and difficulty understanding speech in noise. Cochlear implants remain the standard treatment, providing an effective way of restoring binaural function. Other methods include CROS hearing aids and bone conduction implants. This study evaluated the effectiveness of the Bonebridge bone conduction device for people with SSD who did not meet the criteria for cochlear implantation.
Methods
The study included 52 patients aged between 8 and 58 years who were diagnosed with SSD and underwent Bonebridge implantation surgery. Prior to the procedure, the anatomical condition of the temporal bone was examined using computed tomography. To assess speech understanding in noise, three Matrix tests were performed: Before surgery, at processor activation, and 6 months later. Patients also completed the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire.
Results
Implant surgery was successful in all cases, and postoperative healing proceeded without any major complications. As measured by the APHAB questionnaire, there were significant improvements in the Matrix test results and reductions in hearing difficulties. Some 73% of patients said they would choose a Bonebridge implantation again.
Conclusions
The Bonebridge system is an effective and safe alternative to traditional hearing aids. It is particularly useful for understanding speech in noisy environments and is ideal for patients with SSD who do not meet the criteria for cochlear implantation.
Zitieren
APA
Skarzynski, P. H., Cywka, K. B., Czaplicka, E. A., & Skarzynski, H. (2026). Clinical outcomes and patient-reported benefits of an active bone conduction implant in single-sided deafness: A prospective study. Journal of Clinical Sciences, 23(2), 70-76. https://doi.org/10.4103/jcls.jcls_231_25
Vancouver
Skarzynski PH, Cywka KB, Czaplicka EA, Skarzynski H. Clinical outcomes and patient-reported benefits of an active bone conduction implant in single-sided deafness: A prospective study. Journal of Clinical Sciences. 2026;23(2):70-76. doi:10.4103/jcls.jcls_231_25
BibTeX
@article{Skarzynski2026,
author = {Skarzynski, Piotr Henryk and Cywka, Katarzyna Beata and Czaplicka, Emilia Anna and Skarzynski, Henryk},
title = {Clinical outcomes and patient-reported benefits of an active bone conduction implant in single-sided deafness: A prospective study},
journal = {Journal of Clinical Sciences},
year = {2026},
volume = {23},
number = {2},
pages = {70--76},
doi = {10.4103/jcls.jcls_231_25}
}
EUVIMED