Chairside Photofunctionalization of Titanium Implants: A Clinical Split-mouth Study in Mandibular Overdenture Patients
Journal of Contemporary Dental Sciences · 2026-05 · 3 (2) · 45-52
DOI: 10.4103/jcds.jcds_1_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Contemporary Dental Sciences, online erschienen am 30.05.2026. Verfasst von Mohamed Ahmed Alkhodary und 5 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Ultraviolet (UV) photofunctionalization enhances titanium implant bioactivity by removing surface hydrocarbons and restoring hydrophilicity, improving bone–implant interactions. However, the clinical performance of short-duration UV activation using the DIO UV Activator in overdenture applications remains limited.
Objectives
The objective is to assess the clinical and radiographic effects of 20-s photofunctionalization of titanium implants retaining mandibular complete overdentures. Materials and Methods: In this prospective split-mouth clinical trial, twenty edentulous patients received two mandibular implants each (3.7 mm × 10 mm, Staumann) in a split-mouth design: One implant was photofunctionalized for 20 s using the DIO UV Activator, and the contralateral served as control. Clinical parameters – probing pocket depth (PPD), bleeding on probing (BoP), implant stability quotient (ISQ) – and marginal bone loss (MBL) were evaluated at 3, 6, and 12 months. Data were analyzed using mixed-effects models with significance set at P < 0.05.
Results
All 40 implants survived with uneventful healing. At 3 months, UV-treated implants showed a higher mean ISQ (78.4 ± 3.1) than controls (74.6 ± 3.7; P < 0.05) and lower MBL (0.42 ± 0.18 mm vs. 0.66 ± 0.21 mm; P = 0.002). At 6 months, the UV-treated group maintained superior ISQ (78.6 ± 3.0 vs. 75.8 ± 3.5; P = 0.018), lower PPD (1.81 ± 0.29 mm vs. 1.98 ± 0.34 mm; P = 0.041), and reduced MBL (0.43 ± 0.17 mm vs. 0.55 ± 0.20 mm; P = 0.008). At 12 months, these advantages persisted, with lower PPD (1.86 ± 0.32 mm vs. 2.11 ± 0.39 mm; P = 0.021), less BoP (15% vs. 30%), and significantly lower MBL (0.42 ± 0.18 mm vs. 0.66 ± 0.21 mm; P = 0.002).
Conclusions
A 20-s UV photofunctionalization protocol using the DIO UV Activator significantly enhanced implant stability and reduced marginal bone loss throughout the 12-month follow-up. This rapid, chairside technique is simple, cost-effective, and clinically beneficial for improving osseointegration in mandibular overdenture patients.
Zitieren
APA
Alkhodary, M. A., Altwaijry, A., Alresheedi, B. A., Alharethi, N., Alrethia, R., & Ettesh, A. M. (2026). Chairside Photofunctionalization of Titanium Implants: A Clinical Split-mouth Study in Mandibular Overdenture Patients. Journal of Contemporary Dental Sciences, 3(2), 45-52. https://doi.org/10.4103/jcds.jcds_1_26
Vancouver
Alkhodary MA, Altwaijry A, Alresheedi BA, Alharethi N, Alrethia R, Ettesh AM. Chairside Photofunctionalization of Titanium Implants: A Clinical Split-mouth Study in Mandibular Overdenture Patients. Journal of Contemporary Dental Sciences. 2026;3(2):45-52. doi:10.4103/jcds.jcds_1_26
BibTeX
@article{Alkhodary2026,
author = {Alkhodary, Mohamed Ahmed and Altwaijry, Abdulrahman and Alresheedi, Bandar Awadh and Alharethi, Naji and Alrethia, Rawan and Ettesh, Abeer Mohamed},
title = {Chairside Photofunctionalization of Titanium Implants: A Clinical Split-mouth Study in Mandibular Overdenture Patients},
journal = {Journal of Contemporary Dental Sciences},
year = {2026},
volume = {3},
number = {2},
pages = {45--52},
doi = {10.4103/jcds.jcds_1_26}
}