EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

Comparison of tooth substance loss and angle deviation in access cavity preparation using guided endodontics and conventional method in calcified canals – An in vitro study

Rajinder Kumar Bansal, Manu Bansal, Reeshu Garg, Dolphi Bansal

Journal of Conservative Dentistry and Endodontics · 2025-01 · 28 (1) · 90-95

DOI: 10.4103/jcde.jcde_533_24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Conservative Dentistry and Endodontics, online erschienen am 13.01.2025. Verfasst von Rajinder Kumar Bansal und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Endodontics, Guru Nanak Dev Dental College and Research Institute, Sunam, Punjab, India. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

This study aimed to evaluate the accuracy of access cavity preparation using guided endodontics (GE) and conventional technique (CT) in calcified canals. Subjects and Methods: Twenty teeth with calcification up to middle third were collected after scanning through RadioVisioGraphy (RVG). Preoperative cone-beam computed tomography (CBCT) scan was done and samples were randomly divided into two groups of ten samples each on the basis of method of access cavity preparation. Group 1: Access cavity was prepared by CT, Group 2: Access cavity was prepared by GE. 3D template and corresponding guide drill were made for group 2 samples after performing optical surface scans. After access cavity preparation, postoperative CBCT scanning was performed for all samples. The amount of tooth structure loss and angle deviation were calculated using Sidexis Software. Statistical Analysis Used: The data were analyzed using IBM SPSS Statistics, version 22. A t-test compared tooth structure loss and angle deviation between groups, and a one-way ANOVA calculated tooth structure loss in multiple directions for both groups (P < 0.001).

Results

Our study found that the mean tooth volume loss (17.19 mm 3 ± 06.11 standard deviation [SD]) and angle deviation (4.82° ±01.66 SD) in GE was significantly less (P < 0.001) as compared to mean tooth structure loss (38.85 mm 3 ± 19.07 SD) and angle deviation (13.16° ±2.34 SD) by CT.

Conclusion

GE is more accurate and conservative than CT in management of calcified canals.

Schlagwörter

Stichwörter der Autor:innen

3D templatecalcified canalscone-beam computed tomographyguided endodonticsoptical surface scans

Autor:innen und Institutionen

  • Department of Conservative Dentistry and Endodontics, Guru Nanak Dev Dental College and Research Institute, Sunam, Punjab, India.

Zitieren

APA

Bansal, R. K., Bansal, M., Garg, R., & Bansal, D. (2025). Comparison of tooth substance loss and angle deviation in access cavity preparation using guided endodontics and conventional method in calcified canals – An in vitro study. Journal of Conservative Dentistry and Endodontics, 28(1), 90-95. https://doi.org/10.4103/jcde.jcde_533_24

Vancouver

Bansal RK, Bansal M, Garg R, Bansal D. Comparison of tooth substance loss and angle deviation in access cavity preparation using guided endodontics and conventional method in calcified canals – An in vitro study. Journal of Conservative Dentistry and Endodontics. 2025;28(1):90-95. doi:10.4103/jcde.jcde_533_24

BibTeX
@article{Bansal2025,
  author = {Bansal, Rajinder Kumar and Bansal, Manu and Garg, Reeshu and Bansal, Dolphi},
  title = {Comparison of tooth substance loss and angle deviation in access cavity preparation using guided endodontics and conventional method in calcified canals – An in vitro study},
  journal = {Journal of Conservative Dentistry and Endodontics},
  year = {2025},
  volume = {28},
  number = {1},
  pages = {90--95},
  doi = {10.4103/jcde.jcde_533_24}
}
Kostenlos starten →