Comparative evaluation of the effect of three different obturation techniques on push-out bond strength of AH Plus Bioceramic and EndoCeramic sealers: An in vitro study
Journal of Conservative Dentistry and Endodontics · 2024-10 · 27 (10) · 1026-1031
DOI: 10.4103/jcde.jcde_345_24 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Conservative Dentistry and Endodontics, online erschienen am 05.10.2024. Verfasst von Sayesh Vemuri und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Conservative Dentistry and Endodontics, Sibar Institute of Dental Sciences, Guntur, Andhra Pradesh, India. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Context
Effect of three different obturation techniques on bond strength of bioceramic sealers.
Aim
This study aimed to investigate the effect of cold lateral compaction, thermafil, and thermoplasticized obturation techniques on the push-out bond strength of AH Plus Bioceramic and EndoCeramic sealers. Settings and Design: The design of the study was an in vitro study. Materials and Methods: Forty-two extracted teeth that were single-rooted and had fully developed apices were chosen, decoronated, and biomechanically prepared using rotary nickel–titanium (NiTi) instruments. Samples were divided into two groups of n = 21. Group 1: AH Plus Bioceramic sealer, Group 2: EndoCeramic sealer. Then, based on the obturation technique employed, each group was divided into three subgroups ( n = 7): subgroups 1a, 2a: Cold lateral compaction; Subgroups 1b, 2b: Thermafil; and Subgroups 1c, 2c: Thermoplasticized (obtura). Using universal testing machine, slices from the middle third of the sample’s root were analyzed to determine the push-out bond strength values.
Results
Compared to other groups push-out bond strength was noticeably higher for the cold lateral compaction technique with EndoCeramic sealer (Subgroup 2a), followed by the Thermafil technique with EndoCeramic sealer (Subgroup 2b).
Conclusions
In the present study, compared to heat-based obturation techniques, cold lateral compaction showed better push-out bond strength values for both sealers. EndoCeramic sealer resulted in greater push-out bond strength values than AH Plus Bioceramic sealer.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Conservative Dentistry and Endodontics, Sibar Institute of Dental Sciences, Guntur, Andhra Pradesh, India.
Zitieren
APA
Vemuri, S., Rachamadugu, E. S., Naveena, T., Garlapati, R., Bolla, N., & Basam, R. C. (2024). Comparative evaluation of the effect of three different obturation techniques on push-out bond strength of AH Plus Bioceramic and EndoCeramic sealers: An in vitro study. Journal of Conservative Dentistry and Endodontics, 27(10), 1026-1031. https://doi.org/10.4103/jcde.jcde_345_24
Vancouver
Vemuri S, Rachamadugu ES, Naveena T, Garlapati R, Bolla N, Basam RC. Comparative evaluation of the effect of three different obturation techniques on push-out bond strength of AH Plus Bioceramic and EndoCeramic sealers: An in vitro study. Journal of Conservative Dentistry and Endodontics. 2024;27(10):1026-1031. doi:10.4103/jcde.jcde_345_24
BibTeX
@article{Vemuri2024,
author = {Vemuri, Sayesh and Rachamadugu, Eswar Swetha and Naveena, Thalabhakthula and Garlapati, Roopadevi and Bolla, Nagesh and Basam, Ram Chowdary},
title = {Comparative evaluation of the effect of three different obturation techniques on push-out bond strength of AH Plus Bioceramic and EndoCeramic sealers: An in vitro study},
journal = {Journal of Conservative Dentistry and Endodontics},
year = {2024},
volume = {27},
number = {10},
pages = {1026--1031},
doi = {10.4103/jcde.jcde_345_24}
}
EUVIMED