Could the sealer thickness affect the filling ability of bioceramic endodontic materials? Evaluation in a simulated physiological condition
Journal of Conservative Dentistry and Endodontics · 2025-07 · 28 (7) · 669-674
DOI: 10.4103/jcde.jcde_295_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Conservative Dentistry and Endodontics, online erschienen am 02.07.2025. Verfasst von Laura Issa Matallana und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry, School of Dentistry, São Paulo State University, Araraquara, SP, Brazil. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Context
Bioceramic sealers must provide filling and dimensional stability over time.
Aims
To evaluate by micro-computed tomography (micro-CT), the effect of sealer thickness on the physical properties of Bio-C Sealer (BCS) and BioRoot RCS (BR) after immersion in phosphate-buffered saline (PBS) for 7 and 30 days. Materials and Methods: Extracted bovine teeth were prepared with ProDesign Logic 40/0.05, and the last 4-mm apical of the roots was sectioned. Then, the specimens were filled using the single-cone technique with BCS or BR ( n = 8), providing a smaller sealer thickness (ST) of the apical third and a greater sealer thickness (GT) of the cervical third. The samples were immersed in PBS for 7 and 30 days. After scanning by micro-CT, the volumetric change, material/dentin interface, and filling capacity were assessed. Statistical Analysis Used: ANOVA/Tukey, paired, and unpaired t-tests were performed (α =0.05).
Results
Sealer thickness did not influence the filling capacity in all conditions tested. After 7 days, BR had a higher volume loss than BCS, with no influence of the sealer thickness. The volumetric loss and percentage of interface gaps were higher for both sealers with GT from 7 to 30 days of immersion. BR with GT showed a higher presence of interface gaps compared to the other groups in all the experimental periods.
Conclusions
GT negatively influences the volumetric change and presence of gaps in the material/dentin interface, especially for BR. Both materials demonstrate adequate filling ability regardless of the sealer thickness used.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Restorative Dentistry, School of Dentistry, São Paulo State University, Araraquara, SP, Brazil.
- Departament of Dentistry, Centro Universitário Presidente Antonio Carlos, Barbacena, Brazil.
- Department of Dentistry, Centro Universitário Presidente Tancredo De Almeida Neves, São João Del Rei, Minas Gerais, Brazil.
Zitieren
APA
Matallana, L. I., Santos-Junior, A. O., Tavares, K. I. M. C., Torres, F. F. E., Pinto, J. C., Guerreiro-Tanomaru, J. M., & Tanomaru-Filho, M. (2025). Could the sealer thickness affect the filling ability of bioceramic endodontic materials? Evaluation in a simulated physiological condition. Journal of Conservative Dentistry and Endodontics, 28(7), 669-674. https://doi.org/10.4103/jcde.jcde_295_25
Vancouver
Matallana LI, Santos-Junior AO, Tavares KIMC, Torres FFE, Pinto JC, Guerreiro-Tanomaru JM, et al. Could the sealer thickness affect the filling ability of bioceramic endodontic materials? Evaluation in a simulated physiological condition. Journal of Conservative Dentistry and Endodontics. 2025;28(7):669-674. doi:10.4103/jcde.jcde_295_25
BibTeX
@article{Matallana2025,
author = {Matallana, Laura Issa and Santos-Junior, Airton Oliveira and Tavares, Karina Ines Medina Carita and Torres, Fernanda Ferrari Esteves and Pinto, Jáder Camilo and Guerreiro-Tanomaru, Juliane Maria and Tanomaru-Filho, Mário},
title = {Could the sealer thickness affect the filling ability of bioceramic endodontic materials? Evaluation in a simulated physiological condition},
journal = {Journal of Conservative Dentistry and Endodontics},
year = {2025},
volume = {28},
number = {7},
pages = {669--674},
doi = {10.4103/jcde.jcde_295_25}
}
EUVIMED