EUVIMEDEUVIMED entdecken
Crossref

Hemodynamic Changes during Pneumoperitoneum and Reverse Trendelenburg Position in Bariatric Surgery

Deepak Poudel, Ravinder Kumar Pandey, Amar Pal Bhalla, Ankur Sharma, Bikash Ranjan Ray, Jyotsna Punj, Vanlalnghaka Darlong, Sandeep Aggarwal

Journal of Bariatric Surgery · 2022

DOI: 10.4103/jbs.jbs_12_22 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Bariatric Surgery, 2022. Verfasst von Deepak Poudel und 7 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Patients undergoing bariatric surgeries are at higher perioperative risk due to multiple comorbidities. We studied the hemodynamic changes during pneumoperitoneum and reverse Trendelenburg position in bariatric surgery, using noninvasive cardiac output (CO) monitoring.

Methods

In this prospective observational study, 60 patients of the American Society of Anesthesiologists Grade I–II, aged between 18 and 60 years, planned for elective laparoscopic bariatric surgery were included. During the intraoperative period, hemodynamic monitoring was done using an estimated continuous CO (esCCO) monitor. We noted oxygen saturation (SpO2), heart rate, blood pressure (BP), and CO values obtained before induction of general anesthesia and were compared with values obtained after induction, postintubation, after pneumoperitoneum, after reverse Trendelenburg, and every 10 min during the procedure and postextubation.

Results

The mean baseline SpO2, pulse rate (PR), systolic BP (SBP), diastolic BP (DBP), and CO was 99.17 ± 1.7, 99.9 ± 1.35 bpm, 136.3 ± 14.5 mm Hg, 83.11 ± 10.5 mm Hg, and 7.59 ± 1.44 L/min, respectively. There was a significant fall in PR, SBP, DBP, and CO after induction of anesthesia and intubation ( P = 0.001). After creating pneumoperitoneum and reverse Trendelenburg, the fall in hemodynamic parameters was also significant ( P = 0.001).

Conclusions

The esCCO noninvasive CO monitor can be used in patients undergoing bariatric surgeries and predict CO during surgery.

Zitieren

APA

Poudel, D., Pandey, R. K., Bhalla, A. P., Sharma, A., Ray, B. R., Punj, J., Darlong, V., & Aggarwal, S. (2022). Hemodynamic Changes during Pneumoperitoneum and Reverse Trendelenburg Position in Bariatric Surgery. Journal of Bariatric Surgery. https://doi.org/10.4103/jbs.jbs_12_22

Vancouver

Poudel D, Pandey RK, Bhalla AP, Sharma A, Ray BR, Punj J, et al. Hemodynamic Changes during Pneumoperitoneum and Reverse Trendelenburg Position in Bariatric Surgery. Journal of Bariatric Surgery. 2022. doi:10.4103/jbs.jbs_12_22

BibTeX
@article{Poudel2022,
  author = {Poudel, Deepak and Pandey, Ravinder Kumar and Bhalla, Amar Pal and Sharma, Ankur and Ray, Bikash Ranjan and Punj, Jyotsna and Darlong, Vanlalnghaka and Aggarwal, Sandeep},
  title = {Hemodynamic Changes during Pneumoperitoneum and Reverse Trendelenburg Position in Bariatric Surgery},
  journal = {Journal of Bariatric Surgery},
  year = {2022},
  doi = {10.4103/jbs.jbs_12_22}
}
Kostenlos starten →