EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Outcome of Plate Osteosynthesis in Lateral Third Clavicle Fracture Fixed in Adults

Raghav Agarwal, Chandra Prakash Pal, Ashwani Sadana, Karuna Shanker Dinkar, Hemant Singh Chahar, Amrit Goyal

Journal of Bone and Joint Diseases · 2026-01 · 41 (1) · 1-8

DOI: 10.4103/jbjd.jbjd_9_24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Bone and Joint Diseases, online erschienen am 21.04.2026. Verfasst von Raghav Agarwal und 5 weiteren Autor:innen. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Fractures of the lateral end of the clavicle are relatively uncommon. These fractures are unstable due to the various deforming forces that act on the fragments, as well as the small distal fracture fragment. At most times, the deforming forces are not taken into consideration, and the fracture is not fixed securely. In this study, we assessed a fixation technique using plate osteosynthesis to find out whether it provided a stable fixation with a good functional outcome. Materials and Methods: A total of 32 patients with lateral end clavicle fractures were included in the study. After obtaining informed consent and completing preoperative investigations, open reduction and internal fixation using plate osteosynthesis was performed under the regional (brachial) block. Postoperative X-rays were done on day 1 and every 6 weeks after the operation until the radiological union was achieved. Postoperatively, a universal shoulder immobilizer was given for 2 weeks, followed by active mobilization. Patients were asked to do their daily routine work and avoid lifting heavy weights. The functional outcome was assessed at the end of 6 months with the help of Constant Murley scoring.

Results

There were no intraoperative complications in the procedure. The mean Constant score was 92.91 ± 3.80, with a median of 94 calculated at the end of 6 months. There was one case of hardware irritation. After 1 month of operation, the patient was complaining of irritation and pain in the shoulder. The patient was evaluated, and there was no re-fracture; a universal shoulder immobilizer was given and managed conservatively.

Conclusion

Plate osteosynthesis may be a good method to fix the fractures of the lateral end of the clavicle, which provides a stable fixation with a good functional outcome. It may well be the answer to the fixation questions of the lateral clavicle fractures, although larger comparative studies between the surgical treatment methods are required to confirm the same.

Zitieren

APA

Agarwal, R., Pal, C. P., Sadana, A., Dinkar, K. S., Chahar, H. S., & Goyal, A. (2026). Outcome of Plate Osteosynthesis in Lateral Third Clavicle Fracture Fixed in Adults. Journal of Bone and Joint Diseases, 41(1), 1-8. https://doi.org/10.4103/jbjd.jbjd_9_24

Vancouver

Agarwal R, Pal CP, Sadana A, Dinkar KS, Chahar HS, Goyal A. Outcome of Plate Osteosynthesis in Lateral Third Clavicle Fracture Fixed in Adults. Journal of Bone and Joint Diseases. 2026;41(1):1-8. doi:10.4103/jbjd.jbjd_9_24

BibTeX
@article{Agarwal2026,
  author = {Agarwal, Raghav and Pal, Chandra Prakash and Sadana, Ashwani and Dinkar, Karuna Shanker and Chahar, Hemant Singh and Goyal, Amrit},
  title = {Outcome of Plate Osteosynthesis in Lateral Third Clavicle Fracture Fixed in Adults},
  journal = {Journal of Bone and Joint Diseases},
  year = {2026},
  volume = {41},
  number = {1},
  pages = {1--8},
  doi = {10.4103/jbjd.jbjd_9_24}
}
Kostenlos starten →