Anthropometric analysis of three cervical measurement techniques in the second and third trimesters in Indian females: Single line, two line, and tracing on transvaginal sonography
Journal of Applied & Clinical Radiology · 2025
DOI: 10.4103/jaacr.jaacr_3_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied & Clinical Radiology, 2025. Verfasst von Madeeha Arif Jamadar und 5 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND AND OBJECTIVES: Preterm birth (PTB) is a significant concern due to its association with increased neonatal morbidity and mortality. It is defined as delivery before 37 weeks of gestation. The cervix, the lower part of the uterus, plays a crucial role in maintaining pregnancy through its structural integrity. Shortening of the cervix has been linked to an elevated risk of preterm labor and delivery. Cervical length (CL) measurement during the first trimester of pregnancy has emerged as a valuable tool in predicting the risk of PTB. As cervical ripening start in the second trimester and start dilating in the third trimester which results in variation in CL which may affect fetal outcome. In addition to this, the lower uterine segment “develops” (thins out and becomes more integrated with the body of the uterus) allowing the intrauterine contents to exert direct pressure on the cervix. Various methods have been developed to assess CL. They include single-line, two-line, and tracing techniques on ultrasound. Very less literature is available on the comparison of these three methods. MATERIALS AND METHODS: In this diagnostic prospective study, 40 participants (20 in second trimester and 20 in the third trimester) who were asymptomatic pregnant females between 17 and 45 years of age were selected. Transvaginal sonography (TVS) was done using Samsung RS80A, Samsung RS70A, and Samsung V7 machine with transvaginal probe frequency of 8–10 MHz. Image is magnified so that cervix occupies approximately 50%–75% of the image. The cervix is measured with three different methods single-line, two-line, and tracing method. RESULTS: The mean CL was 32.8 mm (standard deviation [SD]: 4.4) with the single-line method 34.4 mm (SD: 4.7) with the two-line method and 34.5 mm (SD: 4.7) with the tracing method. Both intra- and interoperator agreements were high. The degree of curvature of the cervical canal was variable, with a resultant variability in the difference between the single straight-line measurement and the other two types of measurement. CONCLUSION: Both two-line and tracing methods yield larger measurements than the single-line technique. These do not show statistical differences. Straight-line measurement significantly underestimates the actual CL due to curvature of the cervix in the second and third trimesters.
Zitieren
APA
Jamadar, M. A., Dhote, S., Phatak, S., Mitra, K., Onkar, P., & Bamne, S. (2025). Anthropometric analysis of three cervical measurement techniques in the second and third trimesters in Indian females: Single line, two line, and tracing on transvaginal sonography. Journal of Applied & Clinical Radiology. https://doi.org/10.4103/jaacr.jaacr_3_25
Vancouver
Jamadar MA, Dhote S, Phatak S, Mitra K, Onkar P, Bamne S. Anthropometric analysis of three cervical measurement techniques in the second and third trimesters in Indian females: Single line, two line, and tracing on transvaginal sonography. Journal of Applied & Clinical Radiology. 2025. doi:10.4103/jaacr.jaacr_3_25
BibTeX
@article{Jamadar2025,
author = {Jamadar, Madeeha Arif and Dhote, Sandeep and Phatak, Suresh and Mitra, Kajal and Onkar, Prashant and Bamne, Shivkanta},
title = {Anthropometric analysis of three cervical measurement techniques in the second and third trimesters in Indian females: Single line, two line, and tracing on transvaginal sonography},
journal = {Journal of Applied & Clinical Radiology},
year = {2025},
doi = {10.4103/jaacr.jaacr_3_25}
}
EUVIMED