Abstract (Originalsprache)

Background

Osteoporotic vertebral compression fractures commonly affect the thoracolumbar junction and are associated with substantial pain, immobility, and morbidity. Vertebroplasty offers rapid pain relief and mechanical stabilization but may alter local biomechanics and risk of adjacent-level stress. The current study aims to evaluate stress redistribution in adjacent vertebrae and intervertebral discs following vertebroplasty (VP) using finite element analysis models. Materials and Methods: A patient-specific finite element model of the T11-L3 spine was used to simulate L1 compression fractures and subsequent VP with polymethylmethacrylate (PMMA) or hydroxyapatite (HA) bone cement across three osteoporotic spine models. Stress intensity patterns were evaluated under physiological loading for the T12, L1, and L2 vertebrae, and for the T12-L1 and L1-L2 intervertebral discs. Stress analyses were performed at baseline, post-fracture, and post-VP states.

Results

Fracture induction elevated stress across all examined vertebrae and adjacent discs, with the greatest increases observed at L2 and in both T12-L1 and L1-L2 discs. Vertebroplasty substantially reduced the fracture-induced spike in stress intensity at all levels. However, across all three osteoporotic models, stress levels at T12 (average stress pre-VP: 6.75 × 10 6 Pa; average stress post-VP: 1.40 × 10 7 Pa), T12-L1 (average stress pre-VP: 4.6 × 10 5 Pa; average stress post-VP: 6.54 × 10 5 Pa), and L1-L2 discs (average stress pre-VP: 6.08 × 10 5 Pa; average stress post-VP: 7.375 × 10 5 Pa), remained higher than baseline even after VP. This pattern was consistent for both PMMA and HA cements, with no significant difference between materials. Notably, the L2 vertebrae experienced an approximate five-fold reduction in stress post-VP (average: 1.96 × 10 7 Pa vs baseline average: 1.06 × 10 8 Pa), suggesting effective unloading of the inferior adjacent segment.

Conclusion

VP effectively mitigates fracture-induced stress redistribution but does not fully restore pre-fracture biomechanics, particularly at T12 and adjacent intervertebral discs.

Zitieren

APA

Sudhir, G., Anandan, K., & Kailash, K. (2026). Finite Element Analysis of Stress Variation in Adjacent Vertebrae and Intervertebral Discs after Vertebroplasty for Osteoporotic Vertebral Compression Fractures. Indian Spine Journal. https://doi.org/10.4103/isj.isj_102_25

Vancouver

Sudhir G, Anandan K, Kailash K. Finite Element Analysis of Stress Variation in Adjacent Vertebrae and Intervertebral Discs after Vertebroplasty for Osteoporotic Vertebral Compression Fractures. Indian Spine Journal. 2026. doi:10.4103/isj.isj_102_25

BibTeX
@article{Sudhir2026,
  author = {Sudhir, Ganesan and Anandan, Kavitha and Kailash, Kathik},
  title = {Finite Element Analysis of Stress Variation in Adjacent Vertebrae and Intervertebral Discs after Vertebroplasty for Osteoporotic Vertebral Compression Fractures},
  journal = {Indian Spine Journal},
  year = {2026},
  doi = {10.4103/isj.isj_102_25}
}
Kostenlos starten →