Analysis of hematology quality control using six sigma metrics

Shreya Goel, Amit R Nisal, Ankita Raj, Ravindra C Nimbargi

Indian Journal of Pathology and Microbiology · 2024

DOI: 10.4103/ijpm.ijpm_352_23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Pathology and Microbiology, 2024. Verfasst von Shreya Goel und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, Bharati Vidyapeeth Deemed to be University Medical College Hospital and Research Centre, Pune, Maharashtra, India. Hauptthemen laut MEDLINE: Quality Control, Hematology, Total Quality Management. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Clinical laboratories serve a critical role in increasing the efficiency of patient care. Choosing the right test, getting trustworthy results and appropriate interpretation are of utmost importance in improving the patient’s well-being. Quality management strategies should be applied in routine patient care because laboratory errors have a major impact on the quality of patient care. In sigma metrics, errors identified are quantified as percentage errors or defects per million (DPM). It aims at improving the quality control (QC) process by forming an appropriate strategy. Aim and Objectives: To analyze the internal quality control (IQC) of hematology analytes using the sigma metrics method and to devise the frequency of IQC by the results of six sigma metric analysis. Materials and Methods: This study was conducted in a tertiary care center of western India. Internal quality control (IQC) data sets of five analytes- Red Blood Cell count (RBC), Hemoglobin (Hb), Hematocrit (Hct), White blood cell count (WBC), and Platelet count (PLT) were analyzed retrospectively of six months using Beckman Coulter DXH 800 hematology analyzers.

Results

The observed sigma value was >6 for Hb, TLC, and PLT, indicating excellent results and requiring no modification in IQC. The Sigma value was between 3 and 4 for RBC and Hct suggested the need for improvement in quality control (QC) processes. No analytes showed a Sigma value of

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Quality ControlHematologyTotal Quality ManagementHumansIndiaRetrospective StudiesTertiary Care CentersHematologic TestsLaboratories, ClinicalHemoglobins

Substanzen

Hemoglobins

Autor:innen und Institutionen

  • Department of Pathology, Bharati Vidyapeeth Deemed to be University Medical College Hospital and Research Centre, Pune, Maharashtra, India.

Zitieren

APA

Goel, S., Nisal, A. R., Raj, A., & Nimbargi, R. C. (2024). Analysis of hematology quality control using six sigma metrics. Indian Journal of Pathology and Microbiology. https://doi.org/10.4103/ijpm.ijpm_352_23

Vancouver

Goel S, Nisal AR, Raj A, Nimbargi RC. Analysis of hematology quality control using six sigma metrics. Indian Journal of Pathology and Microbiology. 2024. doi:10.4103/ijpm.ijpm_352_23

BibTeX
@article{Goel2024,
  author = {Goel, Shreya and Nisal, Amit R and Raj, Ankita and Nimbargi, Ravindra C},
  title = {Analysis of hematology quality control using six sigma metrics},
  journal = {Indian Journal of Pathology and Microbiology},
  year = {2024},
  doi = {10.4103/ijpm.ijpm_352_23}
}