EUVIMEDEUVIMED entdecken
Open Access

Measurement of dynamic pupillometry parameters in adult Indian population

Yamini Rattan, Kawalinder K Girgla, Gaurav Mahajan, Pawan Prasher

Indian Journal of Ophthalmology · 2024-11 · 72 (11) · 1611-1617

DOI: 10.4103/ijo.ijo_953_23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 16.04.2024. Verfasst von Yamini Rattan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiology, Sri Guru Ram Das Institute of Medical Sciences and Research, Mehta Road, Sri Amritsar, Punjab, India. Hauptthemen laut MEDLINE: Pupil. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To determine normative dynamic pupillometry data in healthy Indian adults and to investigate the effect of age on various pupillary parameters.

Methods

Pupillometry measurements were obtained on healthy participants using an automatic dynamic pupillometry device, the NPi-200 (NeurOptics Inc., Irvine, CA, USA). Various measurements, including neurologic pupil index (NPi), resting pupil size (Size), minimum pupil diameter (MIN), percentage change in pupil size (CH), constriction velocity (CV), maximum constriction velocity (MCV), latency (LAT), and dilatation velocity (DV), were obtained in routine clinical settings and analyzed statistically for change with age.

Results

A total of 470 participants (470 eyes) were analyzed. Mean NPi was 4.31 ± 0.31, Size was 4.38 ± 0.80 mm, MIN was 2.87 ± 0.49 mm, CH was 34.67 ± 4.15%, CV was 2.74 ± 0.68 mm/s, MCV was 4.16 ± 0.98 mm/s, LAT was 0.23 ± 0.02 s, and DV was 1.13 ± 0.25 mm/s. NPi and LAT were positively correlated ( P < 0.01), whereas Size, MIN, CH, CV, MCV, and DV were negatively correlated with age ( P < 0.01). No statistically significant difference was observed between males and females.

Conclusion

The study offers normative data on dynamic pupillometry parameters across various age groups within a healthy Indian population, which would serve as a reference for future studies in diverse clinical scenarios. It also elucidates that age significantly influences values in the NPi algorithm.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PupilHumansMaleFemaleAdultIndiaMiddle AgedYoung AdultReference ValuesAgedReflex, PupillaryIrisAdolescentDiagnostic Techniques, Ophthalmological

Autor:innen und Institutionen

  • Department of Physiology, Sri Guru Ram Das Institute of Medical Sciences and Research, Mehta Road, Sri Amritsar, Punjab, India.
  • Department of Ophthalmology, Sri Guru Ram Das Institute of Medical Sciences and Research, Mehta Road, Sri Amritsar, Punjab, India.

Zitieren

APA

Rattan, Y., Girgla, K. K., Mahajan, G., & Prasher, P. (2024). Measurement of dynamic pupillometry parameters in adult Indian population. Indian Journal of Ophthalmology, 72(11), 1611-1617. https://doi.org/10.4103/ijo.ijo_953_23

Vancouver

Rattan Y, Girgla KK, Mahajan G, Prasher P. Measurement of dynamic pupillometry parameters in adult Indian population. Indian Journal of Ophthalmology. 2024;72(11):1611-1617. doi:10.4103/ijo.ijo_953_23

BibTeX
@article{Rattan2024,
  author = {Rattan, Yamini and Girgla, Kawalinder K and Mahajan, Gaurav and Prasher, Pawan},
  title = {Measurement of dynamic pupillometry parameters in adult Indian population},
  journal = {Indian Journal of Ophthalmology},
  year = {2024},
  volume = {72},
  number = {11},
  pages = {1611--1617},
  doi = {10.4103/ijo.ijo_953_23}
}
Kostenlos starten →