Pentacam and Corvis ST findings in myopic Chinese patients with different corneal diameters in Singapore

Elizabeth Wen Ling Lim, Hla Myint Htoon, Peng Yi Tan, Marcus Ang, Jodhbir S Mehta, Li Lim

Indian Journal of Ophthalmology · 2024

DOI: 10.4103/ijo.ijo_933_24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, 2024. Verfasst von Elizabeth Wen Ling Lim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Cornea and External Eye Disease Department, Singapore National Eye Centre, 11 Third Hospital Avenue, Singapore. Hauptthemen laut MEDLINE: Myopia, Cornea, Corneal Topography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To study the effect of corneal white-to-white diameter on Pentacam Scheimpflug cornea tomography and Corvis ST corneal visualization Scheimpflug technology parameters in myopic eyes.

Methods

In this retrospective cross-sectional study, 190 eyes of 190 Chinese myopic patients (spherical equivalent range: −1.25 D to −11.00 D) assessed for refractive surgery using Pentacam and Corvis ST devices were included. Patients were divided into groups based on corneal diameter: group A

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MyopiaCorneaCorneal TopographyHumansMaleFemaleCross-Sectional StudiesRetrospective StudiesAdultSingaporeYoung AdultRefraction, OcularAdolescentCorneal PachymetryMiddle AgedEast Asian People

Autor:innen und Institutionen

  • Cornea and External Eye Disease Department, Singapore National Eye Centre, 11 Third Hospital Avenue, Singapore.
  • Cornea Department, Singapore Eye Research Institute, 20 College Rd, Level 6 Discovery Tower, Singapore.
  • Ophthalmology and Visual Sciences Academic Clinical Program, Duke-National University of Singapore Medical School, 8 College Road, Singapore.

Zitieren

APA

Lim, E. W. L., Htoon, H. M., Tan, P. Y., Ang, M., Mehta, J. S., & Lim, L. (2024). Pentacam and Corvis ST findings in myopic Chinese patients with different corneal diameters in Singapore. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_933_24

Vancouver

Lim EWL, Htoon HM, Tan PY, Ang M, Mehta JS, Lim L. Pentacam and Corvis ST findings in myopic Chinese patients with different corneal diameters in Singapore. Indian Journal of Ophthalmology. 2024. doi:10.4103/ijo.ijo_933_24

BibTeX
@article{Lim2024,
  author = {Lim, Elizabeth Wen Ling and Htoon, Hla Myint and Tan, Peng Yi and Ang, Marcus and Mehta, Jodhbir S and Lim, Li},
  title = {Pentacam and Corvis ST findings in myopic Chinese patients with different corneal diameters in Singapore},
  journal = {Indian Journal of Ophthalmology},
  year = {2024},
  doi = {10.4103/ijo.ijo_933_24}
}