EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Value of high-frequency color Doppler ultrasound for preorbital mass diagnosis

Nan Zhang, Jinyong Lin, Rui Hao

Indian Journal of Ophthalmology · 2026

DOI: 10.4103/ijo.ijo_730_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, 2026. Verfasst von Nan Zhang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Visual Function Examination, Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Nankai University Affiliated Ti…. Hauptthemen laut MEDLINE: Ultrasonography, Doppler, Color, Eyelid Neoplasms, Eyelids. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess the diagnostic efficacy of the 18 MHz Color Doppler ultrasound (CDU) probe (L8-18i) in distinguishing benign and malignant preorbital masses and compare its performance with the 11 MHz probe (L3-12).

Methods

A retrospective study analyzed ultrasound data from 17 patients (7 male, 10 female; age 5–80 years) with preorbital masses between May 2021 and April 2024. Patients underwent imaging with both probes, assessing mass size, internal echo characteristics, and blood flow parameters. Results were compared with postoperative pathology using Wilcoxon signed-rank and Mann–Whitney U tests.

Results

Mass locations included the upper eyelid (4), lower eyelid (10), inner canthus (1), brow (1), and conjunctiva (1). Anteroposterior diameters measured by both probes showed no significant difference ( P = 0.320), nor did internal echo characteristics ( P = 0.891). However, blood flow signals differed significantly ( P = 0.014). Pathology revealed benign lesions (chronic inflammation, nevi, cysts, hemangiomas) and malignant tumors (sebaceous gland carcinoma, basal cell carcinoma, squamous cell carcinoma). The L8-18i probe detected significant differences in peak systolic and end-diastolic velocities between benign and malignant masses ( P = 0.048), while the L3-12 probe did not.

Conclusions

The 18 MHz CDU probe demonstrated superior visualization of mass structure and blood flow, improving differentiation between benign and malignant lesions. It enhanced clarity in detecting hemorrhage, necrosis, and septation, offering higher sensitivity and accuracy than the 11 MHz probe, aligning more closely with pathological findings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonography, Doppler, ColorEyelid NeoplasmsEyelidsHumansFemaleRetrospective StudiesAged, 80 and overChild, PreschoolAdolescentAgedMaleMiddle AgedAdultChildYoung AdultDiagnosis, Differential

Stichwörter der Autor:innen

Color Doppler ultrasounddiagnosishigh-frequencypreorbital massesretrospective analysis

Autor:innen und Institutionen

  • Department of Visual Function Examination, Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Nankai University Affiliated Tianjin Eye Hospital, Tianjin, China.
  • Department of Pathology, Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Nankai University Affiliated Tianjin Eye Hospital, Tianjin, China.
  • Department of Strabismus and Pediatric Ophthalmology, Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Nankai University Affiliated Tianjin Eye Hospital, Tianjin, China.

Zitieren

APA

Zhang, N., Lin, J., & Hao, R. (2026). Value of high-frequency color Doppler ultrasound for preorbital mass diagnosis. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_730_25

Vancouver

Zhang N, Lin J, Hao R. Value of high-frequency color Doppler ultrasound for preorbital mass diagnosis. Indian Journal of Ophthalmology. 2026. doi:10.4103/ijo.ijo_730_25

BibTeX
@article{Zhang2026,
  author = {Zhang, Nan and Lin, Jinyong and Hao, Rui},
  title = {Value of high-frequency color Doppler ultrasound for preorbital mass diagnosis},
  journal = {Indian Journal of Ophthalmology},
  year = {2026},
  doi = {10.4103/ijo.ijo_730_25}
}
Kostenlos starten →