Comparison between 80-microns versus 100-microns flap femtosecond LASIK for correction of myopia and myopic astigmatism
Indian Journal of Ophthalmology · 2024
DOI: 10.4103/ijo.ijo_3213_23 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Indian Journal of Ophthalmology, 2024. Verfasst von Sudarshan Khokhar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India. Hauptthemen laut MEDLINE: Keratomileusis, Laser In Situ, Myopia, Astigmatism, Surgical Flaps. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Purpose
This study aimed to compare the safety, efficacy, and visual outcomes of 80-microns LASIK versus 100-microns LASIK in managing myopia and myopic astigmatism. The study was conducted at a tertiary care hospital in North India.
Methods
This was a prospective contralateral eye study that included patients with myopia and myopic astigmatism seeking refractive correction. The eligibility criteria included normal corneal topography, an epithelial thickness less than 60 microns, a calculated percentage tissue ablation (with 100-microns flap) less than 40%, a calculated residual stromal bed thickness (with 100-microns flap) more than 300 microns, and willingness to participate and follow up. Patients with glaucoma, cataracts, other visually disabling ocular pathologies, and a history of past ocular surgery were excluded. All patients underwent LASIK with 80-microns LASIK in one eye and 100-microns LASIK in the other eye. The patients were followed up for 6 months, and the results were analyzed.
Results
The study included 216 eyes of 108 patients. The mean preoperative spherical equivalent in the 80-microns group and the 100-microns group was -3.53 ± 1.81 and -3.69 ± 1.32 diopters, respectively ( P = 0.78). The mean 6 months decimal postoperative UCVA was 0.98 ± 0.13 in the 80-microns group and 0.97 ± 0.14 in the 100-microns group ( P = 0.99). The postoperative change in the higher-order aberration profile was comparable in both groups ( P = 0.78). The percentage tissue ablation was significantly lower in the 80-microns group ( P = 0.002). The incidence of flap micro striae and OBL was higher in the 80-microns group, while neither of these had any visual implications.
Conclusion
The study concluded that 80-microns LASIK is an efficacious and safe alternative to 100-micron LASIK, especially useful in patients with higher myopia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Zitieren
APA
Khokhar, S., Rani, D., Jhajharia, H., Kumar, S., Rathod, A., & Rajput, S. (2024). Comparison between 80-microns versus 100-microns flap femtosecond LASIK for correction of myopia and myopic astigmatism. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_3213_23
Vancouver
Khokhar S, Rani D, Jhajharia H, Kumar S, Rathod A, Rajput S. Comparison between 80-microns versus 100-microns flap femtosecond LASIK for correction of myopia and myopic astigmatism. Indian Journal of Ophthalmology. 2024. doi:10.4103/ijo.ijo_3213_23
BibTeX
@article{Khokhar2024,
author = {Khokhar, Sudarshan and Rani, Deeksha and Jhajharia, Hemant and Kumar, Saumya and Rathod, Aishwarya and Rajput, Sarika},
title = {Comparison between 80-microns versus 100-microns flap femtosecond LASIK for correction of myopia and myopic astigmatism},
journal = {Indian Journal of Ophthalmology},
year = {2024},
doi = {10.4103/ijo.ijo_3213_23}
}
EUVIMED