EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access

Automatic segmentation and quantified analysis of meibomian glands from infrared images

Krishna Poojita Vunnava, Rohit Shetty, Sahana M Prabhu, Piyush Tiwari, Mathew Kurian Kummelil

Indian Journal of Ophthalmology · 2023

DOI: 10.4103/ijo.ijo_2930_22 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Indian Journal of Ophthalmology, 2023. Verfasst von Krishna Poojita Vunnava und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cataract and refractive surgery, Narayana Nethralaya, Bangalore, India. Hauptthemen laut MEDLINE: Eyelid Diseases, Dry Eye Syndromes, Meibomian Gland Dysfunction. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

An algorithm for automated segmentation of meibomian glands from infrared images obtained using a novel prototype infrared hand-held imager has been proposed in this study. Meibomian gland dysfunction (MGD) is quantified in terms of five clinically relevant metrics. A comparison of these metrics in patients with MGD has been presented against a sample of the normative healthy population.

Methods

This is a prospective cross-sectional observational study. Patients presenting to the clinics were enrolled after written informed consent. The everted eyelids of 200 eyes of patients (of which 100 were healthy and 100 were diagnosed with MGD) were imaged using a prototype hand-held camera. The proposed algorithm was used to process the images using enhancement techniques and the glands were automatically segmented. A comparison of glands of normal eyes versus MGD-affected eyes is performed using five metrics presented in this study: (i) drop-out, (ii) length, (iii) width, (iv) the number of glands, and (v) the number of tortuous glands.

Results

The 95% confidence interval for the metrics did not show any overlap between the two groups. In MGD patients, the drop-out ratio was higher than normal. The length and number of glands were significantly lesser than normal. A number of tortuous glands were more in the MGD group. The metrics for MGD versus healthy and cut-off ranges were computed in the results.

Conclusion

The prototype infrared hand-held meibographer and the proposed automatic algorithm for gland segmentation and quantification are effective aids in MGD diagnosis. We present a set of five metrics, which are clinically relevant for guiding clinicians in the diagnosis of MGD.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Eyelid DiseasesDry Eye SyndromesMeibomian Gland DysfunctionHumansMeibomian GlandsCross-Sectional StudiesProspective StudiesTears

Stichwörter der Autor:innen

Automated analysisdry eye diseaseinfrared meibographymeibomian gland dysfunctionnormative data

Autor:innen und Institutionen

  • Department of Cataract and refractive surgery, Narayana Nethralaya, Bangalore, India.
  • Research and Technology Center, Robert Bosch Engg. and Business Solutions, Bangalore, India.

Zitieren

APA

Vunnava, K. P., Shetty, R., Prabhu, S. M., Tiwari, P., & Kummelil, M. K. (2023). Automatic segmentation and quantified analysis of meibomian glands from infrared images. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_2930_22

Vancouver

Vunnava KP, Shetty R, Prabhu SM, Tiwari P, Kummelil MK. Automatic segmentation and quantified analysis of meibomian glands from infrared images. Indian Journal of Ophthalmology. 2023. doi:10.4103/ijo.ijo_2930_22

BibTeX
@article{Vunnava2023,
  author = {Vunnava, Krishna Poojita and Shetty, Rohit and Prabhu, Sahana M and Tiwari, Piyush and Kummelil, Mathew Kurian},
  title = {Automatic segmentation and quantified analysis of meibomian glands from infrared images},
  journal = {Indian Journal of Ophthalmology},
  year = {2023},
  doi = {10.4103/ijo.ijo_2930_22}
}
Kostenlos starten →