Comparison of intraocular lens power prediction by American Society of Cataract and Refractive Surgery formulas and Barrett True-K TK in eyes with prior laser refractive surgery
Indian Journal of Ophthalmology · 2024
DOI: 10.4103/ijo.ijo_2758_23 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Indian Journal of Ophthalmology, 2024. Verfasst von Naren Shetty und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India. Hauptthemen laut MEDLINE: Lenses, Intraocular, Refraction, Ocular, Optics and Photonics. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Purpose
To evaluate the prediction accuracy of various intraocular lens (IOL) power calculation formulas on American Society of Cataract and Refractive Surgery (ASCRS) calculator and Barrett True-K total keratometry (TK) in eyes with previous laser refractive surgery for myopia.
Methods
This retrospective study included eyes with history of myopic laser refractive surgery, which have undergone clear or cataractous lens extraction by phacoemulsification followed by IOL implantation. Those who underwent uneventful crystalline lens extraction were included. Eyes with any complication of refractive surgery or those with eventful lens extraction procedure and those who were lost to follow-up were excluded. Formulas compared were Wang–Koch–Maloney, Shammas, Haigis-L, Barrett True-K no-history formula, ASCRS average power, ASCRS maximum power on the ASCRS post-refractive calculator and the IOLMaster 700 Barrett True-K TK. Prediction error was calculated as the difference between the implanted IOL power and the predicted power by various formulae available on ASCRS online calculator.
Results
Forty post-myopic laser-refractive surgery eyes of 26 patients were included. Friedman’s test revealed that Shammas formula, Barrett True-K, and ASCRS maximum power were significantly different from all other formulas ( P < 0.00001 for each). Median absolute error (MedAE) was the least for Shammas and Barrett True-K TK formulas (0.28 [0.14, 0.36] and 0.28 [0.21, 0.39], respectively) and the highest for Wang–Koch–Maloney (1.29 [0.97, 1.61]). Shammas formula had the least variance (0.14), while Wang–Koch–Maloney formula had the maximum variance (2.66).
Conclusion
In post-myopic laser refractive surgery eyes, Shammas formula and Barrett True-K TK no-history formula on ASCRS calculator are more accurate in predicting IOL powers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Cataract and Refractive Lens Services, Narayana Nethralaya, Bengaluru, Karnataka, India.
- Imaging, Biomechanics and Mathematical Modelling Solutions, Narayana Nethralaya, Bengaluru, Karnataka, India.
Zitieren
APA
Shetty, N., Sathe, P., Aishwarya, Francis, M., & Shetty, R. (2024). Comparison of intraocular lens power prediction by American Society of Cataract and Refractive Surgery formulas and Barrett True-K TK in eyes with prior laser refractive surgery. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_2758_23
Vancouver
Shetty N, Sathe P, Aishwarya, Francis M, Shetty R. Comparison of intraocular lens power prediction by American Society of Cataract and Refractive Surgery formulas and Barrett True-K TK in eyes with prior laser refractive surgery. Indian Journal of Ophthalmology. 2024. doi:10.4103/ijo.ijo_2758_23
BibTeX
@article{Shetty2024,
author = {Shetty, Naren and Sathe, Priyanka and Aishwarya and Francis, Mathew and Shetty, Rohit},
title = {Comparison of intraocular lens power prediction by American Society of Cataract and Refractive Surgery formulas and Barrett True-K TK in eyes with prior laser refractive surgery},
journal = {Indian Journal of Ophthalmology},
year = {2024},
doi = {10.4103/ijo.ijo_2758_23}
}
EUVIMED