Augmented loop myopexy with concurrent intraocular lens implantation for myopic strabismus fixus
Indian Journal of Ophthalmology · 2023
DOI: 10.4103/ijo.ijo_2655_22 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, 2023. Verfasst von Shashikant B Shetty und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Paediatric Ophthalmology and Adult Strabismus, Aravind Eye Hospital and Post Graduate Institute of Ophthalmology, Madurai, Tamil Nadu, …. Hauptthemen laut MEDLINE: Strabismus, Myopia, Esotropia, Cataract. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Purpose
To evaluate safety profile and surgical outcomes of loop myopexy with concurrent intra-ocular lens implantation in cases of myopic strabismus fixus (MSF).
Methods
A retrospective chart review of patients who underwent loop myopexy with concurrent small incision cataract surgery with intra-ocular lens implantation between January 2017 and July 2021 for MSF at a tertiary eye care centre was undertaken. A minimum of 6 months of follow-up after surgery was required for inclusion. The main outcome measures were improvement in alignment postoperatively, improvement in extra-ocular motility postoperatively, intraoperative and postoperative complications and post-operative visual acuity.
Results
12 eyes of 7 patients (male (6): female (1)) underwent modified loop myopexy at a mean age of 46.86 years (range 32-65 years). 5 patients underwent bilateral loop myopexy with intra-ocular lens implantation whereas 2 patients underwent unilateral loop with intra-ocular lens implantation. All eyes underwent additional medial rectus (MR) recession with lateral rectus (LR) plication. At the last follow-up, mean esotropia improved to 16 prism dioptres (PD) (Range: 10-20 PD) from 80 PD (Range:60-90PD), P = 0.016; and success (deviation ≤20PD) was achieved in 73% (95% CI 48 to 89%). Mean hypotropia at presentation was 10 PD (range 6-14 PD), which improved to 0 PD (range 0-9 PD), P = 0.063. Mean BCVA improved from 1.08 LogMar to 0.3 LogMar units.
Conclusion
Loop myopexy combined with intra-ocular lens implantation is a safe and effective procedure in the management of patients who have Myopic Strabismus Fixus with visually significant cataract and improves both visual acuity and ocular alignment significantly.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Paediatric Ophthalmology and Adult Strabismus, Aravind Eye Hospital and Post Graduate Institute of Ophthalmology, Madurai, Tamil Nadu, India.
Zitieren
APA
Shetty, S. B., Aguiar, M., Vijayalakshmi, P., & Pradhan, P. (2023). Augmented loop myopexy with concurrent intraocular lens implantation for myopic strabismus fixus. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_2655_22
Vancouver
Shetty SB, Aguiar M, Vijayalakshmi P, Pradhan P. Augmented loop myopexy with concurrent intraocular lens implantation for myopic strabismus fixus. Indian Journal of Ophthalmology. 2023. doi:10.4103/ijo.ijo_2655_22
BibTeX
@article{Shetty2023,
author = {Shetty, Shashikant B and Aguiar, Marushka and Vijayalakshmi, P and Pradhan, Priyarthi},
title = {Augmented loop myopexy with concurrent intraocular lens implantation for myopic strabismus fixus},
journal = {Indian Journal of Ophthalmology},
year = {2023},
doi = {10.4103/ijo.ijo_2655_22}
}
EUVIMED