EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY-NC-SA 4.0

Comparative evaluation of intraoperative aberrometry and Barrett’s toric calculator in toric intraocular lens implantation

Ritika Mukhija, Murugesan Vanathi, Meena Verma, Nimmy Raj, Noopur Gupta, Radhika Tandon

Indian Journal of Ophthalmology · 2023

DOI: 10.4103/ijo.ijo_2092_22 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Indian Journal of Ophthalmology, 2023. Verfasst von Ritika Mukhija und 5 weiteren Autor:innen. Beteiligte Einrichtung: Cornea, Lens and Refractive Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India. Hauptthemen laut MEDLINE: Lenses, Intraocular, Astigmatism, Phacoemulsification. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Barrett toric calculator (BTC) is known for its accuracy in toric IOL (tIOL) calculation over standard calculators; however, there is no study in literature to compare it with real-time intraoperative aberrometry (IA). The aim was to compare the accuracy of BTC and IA in predicting refractive outcomes in tIOL implantation.

Methods

This was an institution-based prospective, observational study. Patients undergoing routine phacoemulsification with tIOL implantation were enrolled. Biometry was obtained from Lenstar-LS 900 and IOL power calculated using online BTC; however, IOL was implanted as per IA (Optiwave Refractive Analysis, ORA, Alcon) recommendation. Postoperative refractive astigmatism (RA) and spherical equivalent (SE) were recorded at one month, and respective prediction errors (PEs) were calculated using predicted refractive outcomes for both methods. The primary outcome measure was a comparison between mean PE with IA and BTC, and secondary outcome measures were uncorrected distance visual acuity (UCDVA), postoperative RA, and SE at one month. SPSS Version-21 was used; P < 0.05 considered significant.

Results

Thirty eyes of 29 patients were included. Mean arithmetic and mean absolute PEs for RA were comparable between BTC (−0.70 ± 0.35D; 0.70 ± 0.34D) and IA (0.77 ± 0.32D; 0.80 ± 0.39D) ( P = 0.09 and 0.09, respectively). Mean arithmetic PE for residual SE was significantly lower for BTC (-0.14 ± 0.32D) than IA (0.001 ± 0.33D) (−0.14 ± 0.32D; P = 0.002); however, there was no difference between respective mean absolute PEs (0.27 ± 0.21 D; 0.27 ± 0.18; P = 0.80). At one-month, mean UCDVA, RA, and SE were 0.09 ± 0.10D, -0.57 ± 0.26D, and -0.18 ± 0.27D, respectively.

Conclusion

Both IA and BTC give reliable and comparable refractive results for tIOL implantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularAstigmatismPhacoemulsificationHumansAberrometryLens Implantation, IntraocularProspective StudiesRefraction, OcularCornea

Stichwörter der Autor:innen

Barrett toric calculatorORAintraoperative aberrometrytoric IOL

Autor:innen und Institutionen

  • Cornea, Lens and Refractive Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.

Zitieren

APA

Mukhija, R., Vanathi, M., Verma, M., Raj, N., Gupta, N., & Tandon, R. (2023). Comparative evaluation of intraoperative aberrometry and Barrett’s toric calculator in toric intraocular lens implantation. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_2092_22

Vancouver

Mukhija R, Vanathi M, Verma M, Raj N, Gupta N, Tandon R. Comparative evaluation of intraoperative aberrometry and Barrett’s toric calculator in toric intraocular lens implantation. Indian Journal of Ophthalmology. 2023. doi:10.4103/ijo.ijo_2092_22

BibTeX
@article{Mukhija2023,
  author = {Mukhija, Ritika and Vanathi, Murugesan and Verma, Meena and Raj, Nimmy and Gupta, Noopur and Tandon, Radhika},
  title = {Comparative evaluation of intraoperative aberrometry and Barrett’s toric calculator in toric intraocular lens implantation},
  journal = {Indian Journal of Ophthalmology},
  year = {2023},
  doi = {10.4103/ijo.ijo_2092_22}
}
Kostenlos starten →