Ocular surface reconstruction using collagen matrix implant in cases of moderate to severe symblepharon: A pilot study
Indian Journal of Ophthalmology · 2026-04 · 74 (4) · 580-583
DOI: 10.4103/ijo.ijo_1933_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 26.03.2026. Verfasst von S Kavya und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oculoplasty and Ocular Oncology Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, …. Hauptthemen laut MEDLINE: Collagen, Plastic Surgery Procedures, Eyelid Diseases, Conjunctival Diseases. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
To evaluate the safety and efficacy of a collagen matrix implant (CMI) as an adjunct in ocular surface reconstruction for moderate to severe post‐chemical injury symblepharon.
Methods
This prospective interventional pilot study included ten eyes of nine patients (all male, mean age 17.90 ± 9.48 years) with moderate ( n = 4) or severe ( n = 6) symblepharon secondary to chemical injury. All patients underwent symblepharon lysis, followed by ocular surface reconstruction using mucous membrane graft and amniotic membrane graft, with the additional placement of a CMI secured with 6‐0 vicryl sutures. A symblepharon ring was placed postoperatively for 6–8 weeks. All patients were followed for at least 6 months. Surgical success was defined as ≥30% forniceal depth (FD) correction at 3 months, categorized as excellent (75 − 100%), good (60 to
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Oculoplasty and Ocular Oncology Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
- Department of Cornea, Lens, Refractive Surgery, Low Vision Aids and Ocular Oncology, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Zitieren
APA
Kavya, S., Meel, R., Vanathi, M., Pushker, N., & Bajaj, M. S. (2026). Ocular surface reconstruction using collagen matrix implant in cases of moderate to severe symblepharon: A pilot study. Indian Journal of Ophthalmology, 74(4), 580-583. https://doi.org/10.4103/ijo.ijo_1933_25
Vancouver
Kavya S, Meel R, Vanathi M, Pushker N, Bajaj MS. Ocular surface reconstruction using collagen matrix implant in cases of moderate to severe symblepharon: A pilot study. Indian Journal of Ophthalmology. 2026;74(4):580-583. doi:10.4103/ijo.ijo_1933_25
BibTeX
@article{Kavya2026,
author = {Kavya, S and Meel, Rachna and Vanathi, M and Pushker, Neelam and Bajaj, Mandeep S},
title = {Ocular surface reconstruction using collagen matrix implant in cases of moderate to severe symblepharon: A pilot study},
journal = {Indian Journal of Ophthalmology},
year = {2026},
volume = {74},
number = {4},
pages = {580--583},
doi = {10.4103/ijo.ijo_1933_25}
}
EUVIMED